Short and long term results after intracoronary stenting in human coronary arteries: monocentre experience with the balloon-expandable Palmaz-Schatz stent.
نویسندگان
چکیده
OBJECTIVE Intracoronary stenting was designed to overcome acute complications after percutaneous transluminal coronary angioplasty and to achieve a reduced rate of restenosis, both of which are major limitations of this well accepted method for treating coronary heart disease. This report describes the experience at one centre with the implantation of balloon-expandable Palmaz-Schatz stents and focuses on device related complications and the short and long term angiographic outcome. DESIGN A retrospective data analysis. PATIENTS Stenting was attempted in 50 patients. Restenosis after an initially successful angioplasty procedure, inadequate postangioplasty results, saphenous coronary bypass stenoses, and bail-out situations were regarded as indications. MAIN OUTCOME MEASURES AND RESULTS In 49 of 50 attempted patients 61 stents (1-4 per patient) were implanted. Delivery problems occurred in three patients and were successfully overcome in two patients. Bail-out situations were successfully managed in 16 patients. Complications included acute thrombus formation within the stent immediately after implantation in one patient, which was successfully treated by thrombolysis. One patient was sent for bypass surgery the day after implantation; another died 10 days after implantation for unknown reasons. Subacute stent thrombosis occurred in seven patients 5-9 days after implantation and was successfully treated by thrombolysis or balloon angioplasty in five patients. Bleeding complications occurred in nine patients, five of whom required blood transfusions. Angiography showed long term vessel patency after 4-6 months in 31 (76%) of the 41 patients who were followed up, restenosis in six (14%), and reocclusion in four (10%). Late restenosis or reocclusion was found in five (15%) of 33 patients with a single stent in contrast to five (63%) of eight patients with multiple stents. CONCLUSIONS Balloon-expandable intracoronary stenting is a feasible method for treating the acute complications of balloon angioplasty. It reduced the rate of restenosis for single stent implantation. Subacute thrombotic events must be regarded as previously unknown and serious complications.
منابع مشابه
Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model.
AIMS There is increased late loss in luminal diameter following long-term coronary stenting, compared with balloon angioplasty. We evaluated short- and long-term vessel wall injury after experimental implantation of two stent designs as well as balloon angioplasty and their relationship to neointimal hyperplasia. METHODS AND RESULTS Wiktor stents and Palmaz-Schatz stents were implanted in nor...
متن کاملTreating the diabetic patient with coronary disease.
[2] Fishman DL, Leon MB, Bairn DA et al. A randomised comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994; 331: 496-501. [3] Colombo A, Hall P, Nakamura S el al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 1995; 91: 1676-88. [4] Monce MC, Zemour G, Benven...
متن کاملInfluence of expanded balloon diameter on Palmaz-Schatz stent recoil.
After successful stent implantation, the residual luminal diameter of the stented vessel is usually smaller than the maximal stent-expanded balloon diameter. The goal of this study was to determine whether immediate vessel diameter recoil after Palmaz-Schatz stenting is affected by the final expanding balloon diameter used during stent deployment. Single Palmaz-Schatz balloon expandable stents ...
متن کاملRestenosis After Placement of Palmaz - Schatz Stents in Native Coronary Arteries
Background. Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. Methods and Results. To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected fo...
متن کاملBenefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents.
OBJECTIVES This study was designed to evaluate the changes in intrastent and angiographic dimensions when intravascular ultrasound imaging is used to direct the deployment of balloon-expandable Palmaz-Schatz stents in coronary arteries and saphenous vein grafts. BACKGROUND Intravascular ultrasound provides more information than angiography in the imaging of intravascular structures. Previous ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 66 5 شماره
صفحات -
تاریخ انتشار 1991