Blind retrospective motion correction of MR images.

نویسندگان

  • Alexander Loktyushin
  • Hannes Nickisch
  • Rolf Pohmann
  • Bernhard Schölkopf
چکیده

PURPOSE Subject motion can severely degrade MR images. A retrospective motion correction algorithm, Gradient-based motion correction, which significantly reduces ghosting and blurring artifacts due to subject motion was proposed. The technique uses the raw data of standard imaging sequences; no sequence modifications or additional equipment such as tracking devices are required. Rigid motion is assumed. METHODS The approach iteratively searches for the motion trajectory yielding the sharpest image as measured by the entropy of spatial gradients. The vast space of motion parameters is efficiently explored by gradient-based optimization with a convergence guarantee. RESULTS The method has been evaluated on both synthetic and real data in two and three dimensions using standard imaging techniques. MR images are consistently improved over different kinds of motion trajectories. Using a graphics processing unit implementation, computation times are in the order of a few minutes for a full three-dimensional volume. CONCLUSION The presented technique can be an alternative or a complement to prospective motion correction methods and is able to improve images with strong motion artifacts from standard imaging sequences without requiring additional data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autocorrection in MR imaging: adaptive motion correction without navigator echoes.

A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those a...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Volume Reconstruction by Inverse Interpolation: Application to Interleaved MR Motion Correction

We introduce in this work a novel algorithm for volume reconstruction from data acquired on an irregular grid, e.g., from multiple co-registered images. The algorithm, which is based on an inverse interpolation formalism, is superior to other methods in particular when the input images have lower spatial resolution than the reconstructed image. Local intensity bounds are enforced by an L-BFGSB ...

متن کامل

Highly efficient respiratory gating in whole heart MR employing non-rigid retrospective motion correction

Introduction: Three-dimensional whole heart imaging becomes the method of choice in various cardiac applications [1] as it avoids extensive planning of imaging slices and allows reconstructing arbitrary slice orientations. The drawback of the method is a relatively long scan time (on the order of several minutes) which requires motion compensation to suppress motion artifacts. A typical approac...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 70 6  شماره 

صفحات  -