Safety of laboratory analyzers for infection testing - results of the market surveillance by the BfArM until end 2007

نویسندگان

  • R Siekmeier
  • J Halbauer
  • W Mientus
  • D Wetzel
چکیده

The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD) stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA). In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is the responsible CA for most IVD, with a small subset of IVD for immune hematological and infectiological testing as well as tissue typing as specified in Annex II of the Directive, being within the responsibility of the Paul-Ehrlich-Institute (PEI). In this study, all issues regarding laboratory analyzers for infection testing and their consumables, but not reagents, kits and general culture media, reported to the BfArM between begin 1999 and end of 2007 were analyzed in respect to the sources of report, the underlying product failure and the performed corrective actions. Within the observation period a total of 1471 reports for IVD were received of which 73 related to the IVD for infection testing were included in our study. Reports were predominantly received from manufacturers (56) and competent authorities (15). Affected products were most frequently those for immunological analysis (42) whereas those based on culturing techniques (17) and molecular biological techniques (14) played only minor roles. In all these groups, laboratory analyzers (55) were more frequently affected than their consumables (18). Investigations of the manufacturers were able to identify the underlying root causes of product failures in 62 cases (84.9%). In 2 cases (2.7%) the root cause remained unclear and in 9 cases (12.3%) a product failure was excluded or a user error was the underlying cause. Product failures in laboratory analyzers were most frequently caused by software errors (31) and constructional faults (8) whereas the predominant cause of product failure in consumables were errors in production and quality control (8). Manufacturers issued corrective measures in 66 cases (90.4%) from which 49 and 17 were related to laboratory analyzers and their consumables, respectively. Based on the underlying root causes of product failures these were predominantly customer information (48), recalls (40), software-updates (30) and design changes (9) in the product group of laboratory analyzers as well as customer information (16), recalls (12) and modifications of production and quality management (11) in the group of consumables. The results and experiences obtained since 1999 suggest that the system for post marketing surveillance of IVD is an established tool to ensure product safety, even though the current system can be further enhanced.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety of reagents for infection testing: results of the market surveillance by the Federal Institute for Drugs and Medicinal Devices until end 2006.

The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD) stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA). In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is the responsible CA for most...

متن کامل

Safety of in vitro Diagnostics for Hematology and Coagulation Testing – Analysis of the Reports to the German Competent Authority (BfArM)

The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD) stipulates the marketing and postmarketing surveillance of IVD in the European Economic Area. In case of incidents and field-corrective actions related to IVD, manufacturers have to inform the responsible competent authorities. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is the responsible c...

متن کامل

Field safety notices released by manufacturers in cases of failure of products for infection testing: analysis of cases reported to the BfArM between 2005 and 2007

The European Directive 98/79/EC for in vitro diagnostic medical devices (IVD) regulates marketing and post marketing surveillance of IVD in the European Economic Area. Manufacturers have to inform the responsible Competent Authorities (CA) about incidents and field safety corrective actions (FSCA) related to IVD. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is the res...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Finnish Safety and EMC Market Surveillance Statistics

In Finland, electrical safety and EMC market surveillance activities have been collected together in the TUVA database, which contains information on over 10,000 cases. In this paper, the TUVA database is statistically analyzed. The aim of this paper is to ascertain whether there is a potential use and usefulness for the application of these statistics when evaluating the effectiveness of the F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2009