Ablation of Accessory Pathways
نویسنده
چکیده
R ecognition of the possibility of ablating cardiac tissue by means of commonly used electrophysiological catheters has led to the development of the fulguration techniques. Unipolar DC (direct current) shocks delivered at the tip of a catheter by means of an ordinary defibrillator were applied to the atrioventricular node-His bundle area for control of refractory supraventricular tachycardias. This technique was then rapidly extended to other cardiac areas, among which is that of the accessory pathway. Because of its easy access and because of the excellent initial results, high-energy DC shocks initially appeared more suitable for all types of ablation than did radiofrequency alternating current.1-3 However, morbidity and probably long-term mortality of DC shocks were significant, and this was probably due to arcing and barotrauma at the site of energy delivery.4-6 This has stimulated research for a new energy source that could yield the same good results as that of high-energy fulguration yet remaining as safe as radiofrequency current. Based on the concept that voltage and current density rather than barotrauma were responsible for tissue ablation, British workers designed a new ablation system that uses a low-energy power supply connected to a special contoured electrode.7 In vitro and in vivo testing confirmed both effectiveness and lack of deleterious effects of low-energy DC shocks. This has also been shown to have no deleterious effects on dangerous locations such as the coronary sinus.8
منابع مشابه
Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome
Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...
متن کاملTen-year Experience of Radiofrequency Catheter Ablation of Accessory Pathways in Children and Young Adults
Transcatheter radiofrequency ablation of supraventricular tachycardia was first introduced in 1987. The procedure is now well-accepted as primary treatment for supraventricular tachycardia in paediatric patients. In this report we describe our experience of radiofrequency ablation of accessory pathway mediated supraventricular tachycardia in the past 10 years. From 1994 to 2005, 121 procedures ...
متن کاملRecurrence rate after accessory pathway ablation.
OBJECTIVE To evaluate characteristics of patients and accessory pathways as well as additional technical factors involved in the reappearance of accessory pathway conduction after successful ablation. DESIGN Analysis of recurrences after radiofrequency ablation. SETTING 163 consecutive patients with 167 accessory pathways. SUBJECTS 97 men and 66 women with a mean (SD) age of 36 (14) range...
متن کاملGated blood-pool SPECT evaluation of changes after radiofrequency catheter ablation of accessory pathways: evidence for persistent ventricular preexcitation despite successful therapy.
OBJECTIVES This study was designed to prospectively evaluate the effects of radiofrequency ablation in Wolff-Parkinson-White (WPW) syndrome by scintigraphic analysis. BACKGROUND The functional changes triggered by radiofrequency current ablation of atrioventricular accessory pathways are not fully known. METHODS Forty-four patients with WPW syndrome were consecutively investigated before an...
متن کاملCatheter ablation of anteroseptal accessory pathways from the aortic cusps: A case series and a review of the literature
Data regarding catheter ablation of anteroseptal accessory pathways through the aortic cusps are limited. We describe two cases of true para-Hisian accessory pathways successfully ablated from the aortic cusps (right coronary cusp and non-coronary cusp, respectively) along with a review of the current literature. Due to the close proximity to the atrioventricular node and the high risk of compl...
متن کاملElectrocardiographic characteristics and catheter ablation of parahissian accessory pathways.
BACKGROUND Accessory pathways may be located in close proximity to the His bundle, resulting in a high risk of heart block during attempted surgical or electrical interruption of these pathways. This study reports the prevalence, ECG characteristics, and results of catheter ablation of parahissian accessory pathways. They were defined on the basis of both the presence of a high amplitude (> 0.1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005