Fully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF: A Multicenter Study.

نویسندگان

  • Ivan Netuka
  • Poornima Sood
  • Yuriy Pya
  • Daniel Zimpfer
  • Thomas Krabatsch
  • Jens Garbade
  • Vivek Rao
  • Michiel Morshuis
  • Silvana Marasco
  • Friedhelm Beyersdorf
  • Laura Damme
  • Jan D Schmitto
چکیده

BACKGROUND The HeartMate 3 left ventricular assist system (LVAS) is intended to provide long-term support to patients with advanced heart failure. The centrifugal flow pump is designed for enhanced hemocompatibility by incorporating a magnetically levitated rotor with wide blood-flow paths and an artificial pulse. OBJECTIVES The aim of this single-arm, prospective, multicenter study was to evaluate the performance and safety of this LVAS. METHODS The primary endpoint was 6-month survival compared with INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support)-derived performance goal. Patients were adults with ejection fraction ≤ 25%, cardiac index ≤ 2.2 l/min/m(2) without inotropes or were inotrope-dependent on optimal medical management, or listed for transplant. RESULTS Fifty patients were enrolled at 10 centers. The indications for LVAS support were bridge to transplantation (54%) or destination therapy (46%). At 6 months, 88% of patients continued on support, 4% received transplants, and 8% died. Thirty-day mortality was 2% and 6-month survival 92%, which exceeded the 88% performance goal. Support with the fully magnetically levitated LVAS significantly reduced mortality risk by 66% compared with the Seattle Heart Failure Model-predicted survival of 78% (p = 0.0093). Key adverse events included reoperation for bleeding (14%), driveline infection (10%), gastrointestinal bleeding (8%), and debilitating stroke (modified Rankin Score > 3) (8%). There were no pump exchanges, pump malfunctions, pump thrombosis, or hemolysis events. New York Heart Association classification, 6-min walk test, and quality-of-life scores showed progressive and sustained improvement. CONCLUSIONS The results show that the fully magnetically levitated centrifugal-flow chronic LVAS is safe, with high 30-day and 6-month survival rates, a favorable adverse event profile, and improved quality of life and functional status. (HeartMate 3™ CE Mark Clinical Investigation Plan [HM3 CE Mark]; NCT02170363).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A magnetic suspension theory and its application to the HeartQuest ventricular assist device.

Motivated by the design of the HeartQuest magnetically levitated left ventricular assist device, closed form expressions have been developed to compute forces and stiffnesses of magnetic suspensions. The theory applies to any combination of concentric permanent magnet rings, and its accuracy and versatility were verified by experiments. The equations adapt to spreadsheet implementation and nume...

متن کامل

Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months

BACKGROUND: The HeartMate 3 (HM3) Left Ventricular Assist System (LVAS) (Abbott) is a centrifugal, fully magnetically levitated, continuous-flow blood pump engineered to enhance hemocompatibility and reduce shear stress on blood components. The MOMENTUM 3 trial (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) compares the HM...

متن کامل

Heartmate 3 fully magnetically levitated left ventricular assist device for the treatment of advanced heart failure –1 year results from the Ce mark trial

BACKGROUND The HeartMate 3 Left Ventricular Assist System (LVAS) (St. Jude Medical Inc., St Paul, MN) with full magnetic levitation allows for wide and consistent blood flow paths and an artificial pulse designed for enhanced hemocompatibility. The HeartMate 3 received market approval in the European Union in 2015 following completion of a multicenter study. After reaching the 6-month study end...

متن کامل

Left ventricular assist devices: from the bench to the clinic.

The development of ventricular assist devices (VADs) over the past 5 decades as therapy for advanced heart failure (HF) has been extraordinary. Since the original VAD design by Michael DeBakey in the early 1960s, numerous devices for mechanical circulatory support have been engineered, assessed in preclinical studies, applied to human patients in large multicenter clinical trials, and now, sele...

متن کامل

DuraHeart magnetically levitated centrifugal left ventricular assist system for advanced heart failure patients.

The implantable left ventricular assist system (LVAS) using pulsatile pump technology has become an established therapeutic option for advanced heart failure patients. However, there have been technological limitations in some older designs, including a high incidence of infection and mechanical failures associated with moving parts, and the large size of both implantable pump and percutaneous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 66 23  شماره 

صفحات  -

تاریخ انتشار 2015