Three-Dimensional Transoesophageal Echocardiography in Electrophysiology Laboratory.

نویسندگان

  • Mustafa Yildiz
  • Cuneyt Toprak
چکیده

Percutaneous electrophysiological interventions such as atrial fibrillation and ventricular tachycardia ablation are usually monitored by fluoroscopy and electroanatomical mapping systems. Electroanatomical mapping systems lacks soft tissue contrast and adequate visualization of the target area such as right ventricular out-flow tract and left atrium. Recently, real-time 3D transoesophageal echocardiography (RT-3D TEE) has emerged as an important method for visualizing cardiac structures such as left atrium, left atrial appendix, interatrial septum, pulmonary veins, Marshall ligament and mitral valve annulus during invasive procedures. This review aims to describe the RT-3D TEE for the guidance of percutaneous interventional electrophysiological study especially at atrial fibrillation in the cardiac electrophysiology laboratory.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study.

AIMS Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. The aim of the present study was to assess the feasibility, advantages, and safety of RT 3D TEE in...

متن کامل

Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.

AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...

متن کامل

Isolated tricuspid valve prolapsed: identification using two- and three-dimensional echocardiography and transoesophageal echocardiography.

We present a case of isolated prolapse of the tricuspid anterior leaflet in an asymptomatic 34-year-old man who was referred to our hospital for a routine check up. We performed two-and three-dimensional transoesophageal echocardiography (TEE). We found three-dimensional TEE a useful, non-invasive tool that can provide additional information to two-dimensional echocardiography in the assessment...

متن کامل

Dynamic morphology of the secundum atrial septal defect evaluated by three dimensional transoesophageal echocardiography.

OBJECTIVE To define by three dimensional echocardiography the pattern and potential determinants of contraction of a secundum atrial septal defect through the cardiac cycle, and to evaluate the possibility of using cross sectional transthoracic and transoesophageal imaging to assess the dynamic nature of the defect. DESIGN Three dimensional echocardiography was performed using a multiplane tr...

متن کامل

Double transseptal puncture guided by real-time three-dimensional transoesophageal echocardiography during atrial fibrillation ablation.

A 65-year-old man was admitted to our centre because of recurrent drug-resistant episodes of paroxysmal atrial fibrillation, for pulmonary vein radiofrequency catheter ablation. Double transseptal (TS) puncture was performed under realtime three-dimensional transoesophageal echocardiography (RT 3D TEE) guidance. We started by placing a quadripolar catheter in the coronary sinus and a Pigtail ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of atrial fibrillation

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2013