Assessment of liver fibrosis by variable flip angle T1 mapping at 3.0T.
نویسندگان
چکیده
PURPOSE To evaluate the possibility of using a variable flip angle (VFA) T1 mapping technique to diagnose liver fibrosis. MATERIALS AND METHODS Liver fibrosis was induced in rabbits by repetitive administration of carbon tetrachloride (CCl4 ). T1 -weighted magnetic resonance imaging (MRI) was performed in 29 animals (liver fibrosis, n = 18; control, n = 11) using a series of nonenhanced liver acquisition volume acceleration (LAVA) with VFAs at 3.0T. Hepatic T1 relaxation times were measured via regions of interest, which were correlated with subsequent histologic confirmation. The results of T1 mapping in assessment of liver fibrosis were compared with that of apparent diffusion coefficient (ADC) values. RESULTS The mean T1 relaxation time of the control group was the lowest (250.07 ± 88.12 msec), followed by the nonadvanced fibrosis group (387.83 ± 166.58 msec) and the advanced fibrosis group (496.90 ± 291.24 msec). T1 relaxation time measurements differed significantly between the liver fibrosis group and control group (P < 0.05), with a trend of increased mean T1 relaxation times as the fibrotic stage increased. Statistically significant differences were observed between the control group and the nonadvanced fibrosis group (P < 0.05), however with much overlap between the less severe stages. In discriminating between the control group and liver fibrosis group, stage F0-1 (control and stage F1) and stage F2-3, stage F0-2 (control and stage F1-2) and stage F3, area under the receiver operating characteristic (ROC) curves were 0.803 (cutoff value 273.01 msec), 0.712 (cutoff value 371.54 msec), and 0.696 (cutoff value 276.99 msec), respectively. No difference was found between T1 relaxation times and ADC values in assessment of liver fibrosis in our study. CONCLUSION VFA T1 mapping may become a noninvasive imaging tool for the diagnosis of liver fibrosis.
منابع مشابه
Transmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.
PURPOSE To quantify B1+ variation across the breasts and to evaluate the accuracy of precontrast T1 estimation with and without B1+ variation in breast MRI patients at 3 Tesla (T). MATERIALS AND METHODS B1+ and variable flip angle (VFA) T1 mapping were included in our dynamic contrast-enhanced (DCE) breast imaging protocol to study a total of 25 patients on a 3.0T GE MR 750 system. We compute...
متن کاملMyocardial T1 mapping in different cardiomyopathies at 3.0T
Background Diffuse myocardial fibrosis has been described in different cardiomyopathies and has recently been correlated to T1 times measured by cardiac magnetic resonance (CMR). Despite these advances it is yet unknown whether there are differences in T1 maps among these cardiomyopathies and if CMR can distinguish different levels of fibrosis in each category. Moreover, most work on T1 mapping...
متن کاملEffect of changes to Modified Look-Locker Inversion (MOLLI) sequence on T1 Mapping at 3.0 Tesla in healthy volunteers
Background Diffuse myocardial fibrosis may be quantified with cardiovascular magnetic resonance (CMR) by calculating extra-cellular volume (ECV) from native and post-contrast T1 values. T1 values are affected by field strength and acquisition sequence. The Modified Look Locker Inversion Recovery (MOLLI) method of T1 mapping is a widely used approach, but many different acquisition schemes have ...
متن کاملImproved precision in SASHA T1 mapping with a variable flip angle readout
Background The SAturation-recovery single-SHot Acquisition (SASHA) T1 mapping sequence has excellent accuracy independent of T1, T2, heart rate, and flip angle [1], which are known dependencies of the more commonly used MOdified Look-Locker Inversion-recovery (MOLLI) sequence. However, SASHA has a greater T1 variability (poorer precision) compared to MOLLI. A two-parameter fit, with assumed ide...
متن کاملAccurate and Efficient Mapping of Flip Angle and T1 using Simultaneous Actual Flip Angle - Variable Flip Angle Imaging (AFI-T1)
Introduction: The knowledge of flip angle values is essential for accurate modeling in many quantitative MRI techniques. Recently, Actual Flip Angle Imaging (AFI) was proposed to account for multiple sources of flip angle variations such as transmit field inhomogeneity, B0 variations, slab profile, and excitation pulse effects [1]. AFI was successfully applied to yield system-independent T1 rel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 43 3 شماره
صفحات -
تاریخ انتشار 2016