Modified laminar flow biological safety cabinet.

نویسندگان

  • G J McGarrity
  • L L Coriell
چکیده

Tests are reported on a modified laminar flow biological safety cabinet in which the return air plenum that conducts air from the work area to the high efficiency particulate air filters is under negative pressure. Freon gas released inside the cabinet could not be detected outside by a freon gas detection method capable of detecting 10(-6) cc/s. When T3 bacteriophage was aerosolized 5 cm outside the front opening in 11 tests, no phage could be detected inside the cabinet with the motor-filter unit in operation. An average of 2.8 x 10(5) plaque-forming units (PFU)/ft(3) (ca. 0.028 m(3)) were detected with the motor-filter unit not in operation, a penetration of 0.0%. Aerosolization 5 cm inside the cabinet yielded an average of 10 PFU/ft(3) outside the cabinet with the motor-filter unit in operation and an average of 4.1 x 10(5) PFU/ft(3) with the motor-filter unit not in operation, a penetration of 0.002%. These values are the same order of effectiveness as the positive-pressure laminar flow biological safety cabinets previously tested. The advantages of the negative-pressure return plenum design include: (i) assurance that if cracks or leaks develop in the plenum it will not lead to discharge of contaminated air into the laboratory; and (ii) the price is lower due to reduced manufacturing costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory contamination of blood cultures.

A prospective study of the use of a laminar flow cabinet, an exhaust-ventilated safety hood, and the open bench for the microbiological examination of blood is described. Blood samples from 1600 patients were subcultured on the open bench, 2700 in a safety hood, and 2607 in a laminar flow cabinet. Use of the laminar flow cabinet produced a significantly greater level of contamination than the o...

متن کامل

Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the bloo...

متن کامل

Formaldehyde degradation by catalytic oxidation.

Formaldehyde used for the disinfection of a laminar-flow biological safety cabinet was oxidatively degraded by using a catalyst. This technique reduced the formaldehyde concentration in the cabinet from about 5,000 to about 45 mg/m3 in 8 h. This technique should prove useful in other applications.

متن کامل

Performance of exhaust-protective (class I) biological 'safety' cabinets.

Nineteen open-fronted (class I) safety cabinets were subjected to spore containment and airflow tests, which suggested that a flow of 0.75 m/s was the minimum required for safe operation; further tests on three of the cabinets were repeated at different air speeds and confirmed this. The airflow is required to overcome the effect of laboratory or external air currents. Contamination of surfaces...

متن کامل

HEPA EXHAUST FILTER IV HEPA SUPPLY FILTER I / All

A microbiological survey of the effectiveness of class II (laminar flow) 'safety' cabinets found in the UK in the last six years is recorded. Only two of the nine units tested approached the containment of aerosols achieved by a good class I (exhaust protective) cabinet. The others were potentially hazardous if used with pathogenic material. The National Sanitation Foundation and the British St...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 1974