Toxicity and efficacy of three dose-fractionation regimens of intensity-modulated radiation therapy for localized prostate cancer
نویسندگان
چکیده
Outcomes of three protocols of intensity-modulated radiation therapy (IMRT) for localized prostate cancer were evaluated. A total of 259 patients treated with 5-field IMRT between 2005 and 2011 were analyzed. First, 74 patients were treated with a daily fraction of 2.0 Gy to a total of 74 Gy (low risk) or 78 Gy (intermediate or high risk). Then, 101 patients were treated with a 2.1-Gy daily fraction to 73.5 or 77.7 Gy. More recently, 84 patients were treated with a 2.2-Gy fraction to 72.6 or 74.8 Gy. The median patient age was 70 years (range, 54-82) and the follow-up period for living patients was 47 months (range, 18-97). Androgen deprivation therapy was given according to patient risk. The overall and biochemical failure-free survival rates were, respectively, 96 and 82% at 6 years in the 2.0-Gy group, 99 and 96% at 4 years in the 2.1-Gy group, and 99 and 96% at 2 years in the 2.2-Gy group. The biochemical failure-free rate for high-risk patients in all groups was 89% at 4 years. Incidences of Grade ≥ 2 acute genitourinary toxicities were 9.5% in the 2.0-Gy group, 18% in the 2.1-Gy group, and 15% in the 2.2-Gy group (P = 0.29). Cumulative incidences of Grade ≥ 2 late gastrointestinal toxicity were 13% in the 2.0-Gy group at 6 years, 12% in the 2.1-Gy group at 4 years, and 3.7% in the 2.2-Gy group at 2 years (P = 0.23). So far, this stepwise shortening of treatment periods seems to be successful.
منابع مشابه
Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملOut-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer
Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...
متن کامل3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 55 شماره
صفحات -
تاریخ انتشار 2014