An evaluation of the Diamat HPLC analyser for simultaneous determination of haemoglobins A2 and F
نویسندگان
چکیده
The authors describe a modification of the instrumental parameters of the Diamat fully automated HPLC system for Hb A(2) assay (Bio-Rad Laboratories, Milan, Italy) in order to obtain simultaneous determination of Hb A(2) and Hb F.Hb A(2) and Hb F measurements are reproducible (within-run CV 2.6%, with Hb A(2)2.7%; 5.1%, with Hb F 1.3%) and accurate (from a comparison with two microchromatographic techniques for Hb A(2): r = 0.9639 and 0.9755; with two alkali denaturation procedures for Hb F: r = 0.9990 and 0.9952; with radial immunodiffusion, r = 0.9877). Assay linearity has been confirmed for Hb A(2) concentrations between 0 and 6.0%, and for Hb F between 0 and 60%. The data obtained from the analysis of some pathological samples for Hb Bart's, Hb H, Hb J Sardegna, Hb Lepore and Hb S are in agreement with cellulose acetate electrophoresis analysis.The Hb A(2) reference intervals for normals (N = 597) and Beta-thalassemia carriers (N = 200) are respectively (95% limits) 2.02-3.27 and 3.92-5.90 in % units. Hb F values measured in normals (N = 968), in beta-thal carriers (N = 302) and in deltabeta-thal carriers (N =3) have been found to be consistent with the usual diagnostic parameters.SOME MINOR LIMITATIONS EMERGED: the most relevant concerns Hb A(1c), which is overestimated with respect to a reference method (y = 1.217x + 0.16; N = 79; r = 0.9235). A probable interference from labile fractions is responsible for this Hb A(1c) inaccuracy.
منابع مشابه
Assessment of an automatic liquid chromatograph for foetal and abnormal haemoglobins.
The DIAMAT TM (Bio-Rad) analyser is a microprocessor-operated HPLC system using a silica-based weak cation exchange column with three phosphate buffers of increasing ionic strength as the step gradient mobile phase. A dual wavelength detector measures absorbance at 415 and 690 nm; each sample is completely processed in 8 minutes. The instrument effectively separates and quantifies HbF in a disc...
متن کاملDevelopment a HPLC method for simultaneous determination of Azinphose methyl, Diazinon, Phosalone and Chlorpyrifos residues in fruit
A high-performance liquid chromatography with ultraviolet detection (HPLC/UV) methodwhich was used solid-phase extraction for cleanup, was developed for the determination ofAzinphos methyl ,Phosalone, Diazinon and Chlorpyrifos residues in fruits. A full factorialexperimental design was used for development of HPLC condition and evaluation of effect ofthree factors (pH of mobile phase, percent o...
متن کاملAn Ion-pair Dispersive Liquid-Liquid Microextraction for Simultaneous Determination of Synthetic Dyes in Ice Cream Samples by HPLC
An efficient, sensitive and fast method was developed based on an ultrasound-assisted extraction followed by an ion-pair dispersive liquid-liquid microextraction (USAE-IP-DLLME) for the simultaneous determination of five commonly used synthetic sulfonate dyes (tartarazine, quinoline yellow, sunset yellow, azorubine, and brilliant blue) in ice cream samples using high performance liquid chromato...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 11 شماره
صفحات -
تاریخ انتشار 1989