Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
نویسندگان
چکیده
INTRODUCTION Blood pressure measurements frequently guide management in critical care. Direct readings, commonly from a major artery, are considered to be the gold standard. Because arterial cannulation is associated with risks, alternative noninvasive blood pressure (NIBP) measurements are routinely used. However, the accuracy of NIBP determinations in overweight patients in the outpatient setting is variable, and little is known about critically ill patients. This prospective, observational study was performed to compare direct intra-arterial blood pressure (IABP) with NIBP measurements obtained using auscultatory and oscillometric methods in overweight patients admitted to our medical intensive care unit. METHOD Adult critically ill patients with a body mass index (BMI) of 25 kg/m2 or greater and a functional arterial line (assessed using the rapid flush test) were enrolled in the study. IABP measurements were compared with those obtained noninvasively. A calibrated aneroid manometer (auscultatory technique) with arm cuffs compatible with arm sizes and a NIBP monitor (oscillometric technique) were used for NIBP measurements. Agreement between methods was assessed using Bland-Altman analysis. RESULTS Fifty-four patients (23 males) with a mean (+/- standard error) age of 57 +/- 3 years were studied. The mean BMI was 34.0 +/- 1.4 kg/m2. Mean arm circumference was 32 +/- 0.6 cm. IABP readings were obtained from the radial artery in all patients. Only eight patients were receiving vasoactive medications. Mean overall biases for the auscultatory and oscillometric techniques were 4.1 +/- 1.9 and -8.0 +/- 1.7 mmHg, respectively (P < 0.0001), with wide limits of agreement. The overestimation of blood pressure using the auscultatory technique was more important in patients with a BMI of 30 kg/m2 or greater. In hypertensive patients both NIBP methods underestimated blood pressure as determined using direct IABP measurement. CONCLUSION Oscillometric blood pressure measurements underestimated IABP readings regardless of patient BMI. Auscultatory measurements were also inaccurate, tending to underestimate systolic blood pressure and overestimate mean arterial and diastolic blood pressure. NIBP can be inaccurate among overweight critically ill patients and lead to erroneous interpretations of blood pressure.
منابع مشابه
Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملNoninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
BACKGROUND Monitoring of cardiac output and blood pressure are standard procedures in critical care medicine. Traditionally, invasive techniques like pulmonary artery catheter (PAC) and arterial catheters are widely used. Invasiveness bears many risks of deleterious complications. Therefore, a noninvasive reliable cardiac output (CO) and blood pressure monitoring system could improve the safety...
متن کاملPeripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study
INTRODUCTION Invasive arterial blood pressure monitoring is a common practice in intensive care units (ICUs). Accuracy of invasive blood pressure monitoring is crucial in evaluating the cardiocirculatory system and adjusting drug therapy for hemodynamic support. However, the best site for catheter insertion is controversial. Lack of definitive information in critically ill patients makes it dif...
متن کاملتأثیر بازآموزی ساکشن لوله داخل تراشه برای پرستاران، بر تغییرات فشارخون بیماران بستری در بخش مراقبت ویژه
Background & Aim: Endotracheal suctioning (ETS) is a common invasive nursing procedure. Hemodynamic parameters changes during and after the procedure. If appropriate strategies do not be applied during the ETS, hemodynamic changes can be significant and life threatening in critically ill patients. The purpose of this study was to assess the effect of education of endotracheal suctioning on pati...
متن کاملذخیره در منابع من