Imaging of central airway stenting with multidetector computed tomography

نویسنده

  • Giovacchino Pedicelli
چکیده

UNLABELLED BACKGROUND Multidetector computed tomography (MDCT) provides guidance for primary screening of the central airways. The aim of our study was assessing the contribution of multidetector computed tomography- two dimensional reconstruction in the management of patients with tracheobronchial stenosis prior to the procedure and during a short follow up period of 3 months after the endobronchial treatment. METHODS This is a retrospective study with data collected from an electronic database and from the medical records. Patients evaluated with MDCT and who had undergone a stenting procedure were included. A Philips RSGDT 07605 model MDCT was used, and slice thickness, 3 mm; overlap, 1.5 mm; matrix, 512x512; mass, 90 and kV, 120 were evaluated. The diameters of the airways 10 mm proximal and 10 mm distal to the obstruction were measured and the stent diameter (D) was determined from the average between D upper and D lower. RESULTS Fifty-six patients, 14 (25%) women and 42 (75%) men, mean age 55.3 ± 13.2 years (range: 16-79 years), were assessed by MDCT and then treated with placement of an endobronchial stent. A computed tomography review was made with 6 detector Philips RSGDT 07605 multidetector computed tomography device. Endobronchial therapy was provided for the patients with endoluminal lesions. Stents were placed into the area of stenosis in patients with external compression after dilatation and debulking procedures had been carried out. In one patient the migration of a stent was detected during the follow up period by using MDCT. CONCLUSIONS MDCT helps to define stent size, length and type in patients who are suitable for endobronchial stinting. This is a non-invasive, reliable method that helps decisions about optimal stent size and position, thus reducing complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Low insertion of a cystic duct into the common bile duct as a cause for a malpositioned biliary stent: demonstration with multidetector computed tomography.

Anatomical variations of the extrahepatic biliary system are common. Adequate knowledge of such variations and an appropriate roadmap before any surgical, endoscopic or percutaneous procedure/intervention help in preventing associated complications. Multiple imaging modalities can depict the anatomy of the extrahepatic biliary tree. High resolution magnetic resonance imaging and magnetic resona...

متن کامل

The Accuracy of Noninvasive Imaging Techniques in Diagnosis of Carotid Plaque Morphology

BACKGROUND The stroke is leading cause of death and severe disability worldwide. Atherosclerosis is responsible for over 30% of all ischemic strokes. It has been recently discovered that plaque morphology may help predict the clinical behavior of carotid atherosclerosis and determine the risk of stroke. The noninvasive imaging techniques have been developed to evaluate the vascular wall in an a...

متن کامل

Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.

PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location an...

متن کامل

Isolated spontaneous renal artery dissection: diagnosis and endovascular management.

Spontaneous, isolated focal renal artery dissection is an extremely rare cause of renovascular hypertension. Imaging technology for the renal arteries has evolved recently with the development of multidetector computed tomography angiography (CTA), and intravascular ultrasound. We describe a 52-year-old man with spontaneous renal artery dissection complicated by renovascular hypertension, succe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012