Accuracy of Continuous Glucose Monitoring (CGM) during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus

نویسندگان

  • Othmar Moser
  • Julia K. Mader
  • Gerhard Tschakert
  • Alexander Mueller
  • Werner Groeschl
  • Thomas R. Pieber
  • Gerd Koehler
  • Janin Messerschmidt
  • Peter Hofmann
چکیده

Continuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP₁), and 5% below the second lactate turn point (LTP₂) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05). In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (-3.44, 5.15) mmol·L(-1), -0.45 (-3.95, 3.05) mmol·L(-1), -0.31 (-8.83, 8.20) mmol·L(-1) and at 1.17 (-2.06, 4.40) mmol·L(-1), 0.11 (-5.79, 6.01) mmol·L(-1), 1.48 (-2.60, 5.57) mmol·L(-1) in HIIE for the same intensities. Clinically-acceptable results (except for CON H) were found. CGM estimated BG to be clinically acceptable, except for CON H. Additionally, using CGM may increase avoidance of exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Continuous Glucose Monitoring before, during, and after Aerobic and Anaerobic Exercise in Patients with Type 1 Diabetes Mellitus

Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions an...

متن کامل

The Effects of Free-Living Interval- Walking Training on Glycemic Control, Body Composition, and Physical Fitness in Type 2 Diabetes Patients A randomized, controlled trial

RESEARCHDESIGNANDMETHODSdSubjects with type 2 diabetes were randomized to a control (n = 8), continuous-walking (n = 12), or interval-walking group (n = 12). Training groups were prescribed five sessions per week (60 min/session) and were controlled with an accelerometer and a heart-rate monitor. Continuous walkers performed all training at moderate intensity, whereas interval walkers alternate...

متن کامل

Sensor Monitoring of Physical Activity to Improve Glucose Management in Diabetic Patients: A Review

Diabetic individuals need to tightly control their blood glucose concentration. Several methods have been developed for this purpose, such as the finger-prick or continuous glucose monitoring systems (CGMs). However, these methods present the disadvantage of being invasive. Moreover, CGMs have limited accuracy, notably to detect hypoglycemia. It is also known that physical exercise, and even da...

متن کامل

The Effect of Interval and Continuous Training on Angiogenesis Factor in Type2 Diabetic Wistar Rats

Objective: The equilibrium of angiogenesis stimulus agents and angiogenesis inhibitory agents is an important factor in the increase of diabetic cardiomyopathy. This research aimed to survey the result of eight weeks of high-intensity interval training (HIIT) and moderate continuous (MICT) on the myocardium angiogenesis agent and histological alterations within male diabetic rats. Materials an...

متن کامل

Accuracy assessment of online glucose monitoring by a subcutaneous enzymatic glucose sensor during exercise in patients with type 1 diabetes treated by continuous subcutaneous insulin infusion.

AIM Online continuous glucose monitoring (CGM) during physical exercise would be highly useful in patients with insulin-treated diabetes. For this reason, this study assessed whether such a goal could be reached with a subcutaneous 'needle-type' enzymatic sensor. METHODS Ten patients (five women/five men), aged 51 ± 12 years, with type 1 diabetes for 24 ± 11 years treated by continuous subcut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016