Range of motion predictability after total knee arthroplasty with medial pivot prosthesis☆

نویسندگان

  • Lúcio Honório de Carvalho Júnior
  • Bruno Presses Teixeira
  • Cláudio Otávio da Silva Bernardes
  • Luiz Fernando Machado Soares
  • Matheus Braga Jacques Gonçalves
  • Eduardo Frois Temponi
چکیده

OBJECTIVE To assess whether there the final range of motion (ROM) results achieved by patients undergoing total knee arthroplasty (TKA) with prosthesis using Medial Pivot design are predictable. METHODS Between January and August of 2014, 155 patients with primary osteoarthritis of knee who underwent TKA using the prosthesis ADVANCE® Medial Pivot were prospectively assessed. All ROM measures were made and recorded before, during, and after surgery. All patients were clinically assessed preoperatively and postoperatively (15, 45 days, three months, six months, one year, and annually thereafter after surgery); their functional status was assessed using the WOMAC questionnaire. RESULTS Significant differences (p < 0.001) were observed between the means and medians of ROM in the preoperative when compared with those during the perioperative; the perioperative values, when compared with those after six months postoperative, were also different (p < 0.001). No significant differences were found between the means and medians ROM between the intraoperative period and at the 45-day assessment (ns) and between the means and medians ROM between the preoperative period and at the six-month evaluation (ns). CONCLUSION The final ROM achieved by patients that underwent TKA with medial pivot prosthesis can be predicted. The perioperative ROM correlates with that at 45 days after surgery. The final ROM is correlated with that of the pre-operative period.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...

متن کامل

Correlation between knee kinematics and patellofemoral contact pressure in total knee arthroplasty.

The aim of this study is to evaluate the relationship between patellofemoral contact stress and intraoperative knee kinematic patterns after mobile bearing total knee arthroplasty (TKA). Medial osteoarthritic knees of forty-six posterior-stabilized total knee prostheses were evaluated using a computed tomography-guided navigation system. Subjects were divided into two groups based on intraopera...

متن کامل

Primary Total Knee Arthroplasty for Simple Distal Femoral Fractures in Elderly Patients with Knee Osteoarthritis

PURPOSE Primary total knee arthroplasty (TKA) can be an alternative method for treating distal femoral fractures in elderly patients with knee osteoarthritis. The purpose of this study was to evaluate the clinical and radiographic results in patients with knee osteoarthritis who underwent TKA with the Medial Pivot prosthesis for distal femoral fractures. MATERIALS AND METHODS Eight displaced ...

متن کامل

Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants.

Contemporary posterior cruciate-retaining total knee designs have provided pain relief and improved knee function but have failed to reproduce the kinematics and stability of the normal nonarthritic knee. The Medial Pivot total knee design features a near constant radius of curvature of the femoral component. The tibial surface is highly congruent and asymmetric, permitting a medial pivot motio...

متن کامل

In vivo weight-bearing kinematics with medial rotation knee arthroplasty.

Knee arthroplasties are designed to accommodate flexion, axial rotation and anteroposterior (AP) translation. Axial rotation during extension varies, with some rotating platform devices allowing unrestricted rotation while some conforming fixed-bearing designs almost none. The purpose of this study was to examine in vivo kinematics of a fixed-bearing medial rotation-type arthroplasty (MRK) duri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2017