Efficient extraction of a collimated ultra-cold neutron beam using diffusive channels
نویسندگان
چکیده
We present a first experimental demonstration of a new method to extract a wellcollimated beam of ultra-cold neutrons (UCN) from a storage vessel. Neutrons with too large divergence are not removed from the beam by an absorbing collimation, but a diffuse or semidiffuse channel with high Fermi potential reflects them back into the vessel. This avoids unnecessary losses and keeps the storage time high, which may be beneficial when the vessel is part of a UCN source with long buildup time of a high UCN density. PACS: 28.20.-v, 28.20.Gd, 29.25.Dz, 28.41.Rc
منابع مشابه
چشمههای نوترون فوقسرد: آهنگ تولید نوترون فوقسرد در مبدل دوتریم
A new model is presented herein to calculate optimal value for ultra-cold neutron (UCN) production rate of a UCN source. The cold neutron (CN) converter is the main component of UCN source. In this paper, we study the UCN source which contains the D2O neutron moderator, the sD2 converter, 590 Mev proton beam, and the spallation target (a mixture of Pb, D2O and Zr). In order to determine the qua...
متن کاملde The ( n , ) campaigns at EXILL
At the PF1B cold neutron beam line at the Institut Laue Langevin, the EXILL array consisting of EXOGAM, GASP and ILL-Clover detectors was used to perform (n, ) measurements at very high coincidence rates. About ten different reactions were measured in autumn 2012 using a highly collimated cold neutron beam. In spring 2013, the EXOGAM array was combined with 16 LaBr3(Ce) scintillators in the EXI...
متن کاملLocking and wavelength selection of an ultra-collimated single-mode diode laser bar by a volume holographic grating.
Wavelength-locking by a volume holographic grating (VHG) is reported for a diode laser bar with 49 single mode emitters, fitted with a dual-axis collimation phase-plate for smile elimination and excellent beam pointing correction. The much-improved VHG feedback with the ultra-collimated array beam gives 100% wavelength locking at 975 nm over a 17°C temperature range and external cavity lengths ...
متن کاملThe Spallation Target for the Ultra Cold Neutron Source Ucn
A source of ultra cold neutrons, based on the spallation process is under construction at PSI. With the help of a fast kicker the whole ~1 MW proton beam (590 MeV, 2 mA) from the accelerator will be switched onto the UCN spallation target for approximately 8 seconds every 15 minutes. The spallation neutrons are thermalized in a large heavywater moderator at room temperature and further cooled i...
متن کاملAdapting a triple-axis spectrometer for small angle neutron scattering measurements.
Small angle neutron scattering (SANS) instruments typically cover a q (scattering vector) range from 0.001 to 0.6 A(-1). This range in q is achieved through a combination of cold neutrons (lambda>4 A) and a highly collimated beam. However, as a direct result of the unavailability of a cold source at the Canadian Neutron Beam Centre (CNBC), we have resorted to adapting a triple-axis spectrometer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007