Elective haemodialysis increases exhaled isoprene.

نویسندگان

  • Philipp Lirk
  • Florian Bodrogi
  • Hartmann Raifer
  • Karin Greiner
  • Hanno Ulmer
  • Josef Rieder
چکیده

BACKGROUND Uraemic odour is a characteristic feature of patients with end-stage renal disease (ESRD). However, few investigations have been carried out into the composition of exhaled air in ESRD patients undergoing haemodialysis (HD). Increases of exhaled isoprene levels by a factor of up to 2.7 following HD have been reported. METHODS We attempted to confirm these findings in 50 patients undergoing HD using haemophan (n=23) or polysulphone (n=27) dialysis membranes. Parallel evaluation of ambient air, calorie intake, medication and haemodynamic variables was performed. Samples were analysed using proton transfer reaction-mass spectrometry (PTR-MS). RESULTS Significant changes in breath isoprene concentration were observed when comparing patients before [39.14+/-14.96 parts per billion (ppbv)] and after (63.54+/-27.59 ppbv) dialysis (P<0.001). The quotient of values before and after dialysis was 1.84 (SD 1.41). No significant differences in isoprene kinetics were found between the use of haemophan and polysulphone membranes. No significant correlations were observed between isoprene quotients and variations in blood pressure during HD, calorie intake, ingestion of lipid-lowering drugs or serum lipid levels. CONCLUSIONS Isoprene concentration was higher in the exhaled air of patients after HD as compared with values before HD. Large interindividual variability existed in isoprene kinetics. Oxidative stress appears to be an unlikely cause for this rise. An alternative hypothesis is an influence of respiratory variables on isoprene exhalation based upon Henry's law constant. We therefore propose to perform online monitoring of isoprene exhalation by PTR-MS during the HD session to investigate the possible influence of respiratory variables.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isoprene and acetone concentration profiles during exercise on an ergometer.

A real-time recording setup combining exhaled breath volatile organic compound (VOC) measurements by proton transfer reaction-mass spectrometry (PTR-MS) with hemodynamic and respiratory data is presented. Continuous automatic sampling of exhaled breath is implemented on the basis of measured respiratory flow: a flow-controlled shutter mechanism guarantees that only end-tidal exhalation segments...

متن کامل

Breath isoprene--aspects of normal physiology related to age, gender and cholesterol profile as determined in a proton transfer reaction mass spectrometry study.

BACKGROUND This study was performed to clarify variations in breath isoprene concentrations with age, gender, body mass index (BMI) and total serum cholesterol. Our cohort consisted of 205 adult volunteers of different smoking background without health complaints. Total cholesterol in blood serum was measured in 79 of these volunteers. METHODS Mixed expiratory exhaled breath was sampled using...

متن کامل

Effect of the influenza A (H1N1) live attenuated intranasal vaccine on nitric oxide (FE(NO)) and other volatiles in exhaled breath.

For the 2009 influenza A (H1N1) pandemic, vaccination and infection control were the main modes of prevention. A live attenuated H1N1 vaccine mimics natural infection and works by evoking a host immune response, but currently there are no easy methods to measure such a response. To determine if an immune response could be measured in exhaled breath, exhaled nitric oxide (FE(NO)) and other exhal...

متن کامل

The role of mathematical modeling in VOC analysis using isoprene as a prototypic example.

Isoprene is one of the most abundant endogenous volatile organic compounds (VOCs) contained in human breath and is considered to be a potentially useful biomarker for diagnostic and monitoring purposes. However, neither the exact biochemical origin of isoprene nor its physiological role is understood in sufficient depth, thus hindering the validation of breath isoprene tests in clinical routine...

متن کامل

Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study

BACKGROUND Volatile breath biomarkers provide a non-invasive window to observe physiological and pathological processes in the body. This study was intended to assess the impact of heart surgery with extracorporeal circulation (ECC) onto breath biomarker profiles. Special attention was attributed to oxidative or metabolic stress during surgery and extracorporeal circulation, which can cause org...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2003