Intraluminal albumin stent assisted laser welding for ureteral anastomosis.

نویسندگان

  • Hua Xie
  • Brian S Shaffer
  • Scott A Prahl
  • Kenton W Gregory
چکیده

BACKGROUND AND OBJECTIVES The success of laser tissue welding or soldering depends on optimal laser settings, solder material, and tissue type and geometry. To develop a practical laser welding technique for ureteral repair, an intraluminal albumin stent was designed to enhance the welding effects on ureteral end to end anastomosis. STUDY DESIGN/MATERIALS AND METHODS In vitro porcine ureters were anastomosed using an albumin stent alone, the albumin stent plus a solder, and the solder alone. All welding was performed with an 810-nm diode laser with either a continuous wave (1 W, CW) or two pulse modes (2 W, 3.3 Hz; 1 W, 5 Hz). Laser parameters, tensile strength (TS) and burst pressure (BP) of the ureteral anastomosis, and tissue thermal injury were measured. RESULTS In the 2-W pulse mode, BP in the albumin stent plus solder group (mean 185 mmHg) and the stent only group (mean 133 mmHg) were significantly higher than the solder only group (mean 77 mmHg, P < 0.05). Laser ureteral anastomosis with the stent plus solder group at 1-W CW and 2-W pulse laser modes yielded the highest TS (mean 97, 82 g) and BP (mean 183, 185 mmHg). Among the three modes, the 1 W pulse delivered the lowest energy and yielded the lowest TS and BP in ureteral anastomosis. There was no significant difference in the thermal damage to the tissue among the modes and groups. CONCLUSIONS Using the albumin stent increased the reliability of ureter end-to-end laser anastomosis. Further studies will be warranted in vivo and other tubular organs as well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser ureteral anastomosis using intraluminal albumin stent in a porcine model.

BACKGROUND AND OBJECTIVES We compared ureteral anastomosis using a laser and intraluminal albumin stent with both conventional suturing and laser soldering techniques. STUDY DESIGN/MATERIALS AND METHODS Twelve pigs underwent bilateral ureteral anastomoses (N = 24) using one of the three anastomotic methods: (1) laser welding with intraluminal albumin stent (N = 11); (2) with albumin solder (N...

متن کامل

Lasers in Surgery and Medicine 32:294–298 (2003) Laser Ureteral Anastomosis Using Intraluminal Albumin Stent in a Porcine Model

Background and Objectives: We compared ureteral anastomosis using a laser and intraluminal albumin stent with both conventional suturing and laser soldering techniques. Study Design/Materials and Methods: Twelve pigs underwent bilateral ureteral anastomoses (N1⁄4 24) using one of the three anastomotic methods: (1) laser welding with intraluminal albumin stent (N1⁄4 11); (2) with albumin solder ...

متن کامل

Sutureless End to End Ureteral Anastomosis Using a New Albumin Stent and Diode Laser

Sutureless end to end ureteral anastomoses was successfully constructed in acute and chronic experiments. A photothermal sensitive hydrolyzable (PSH) albumin stent played roles as solder and intraluminal supporter to adhesion and position the anastomosed ureter by end to end fashion. The anastomosis seam was lased with 810 nm diode laser energy supplied through hand-held 600 mm noncontact optic...

متن کامل

Laser Welding with an Albumin Stent: Experimental Ureteral End to End Anastomosis

Porcine ureters were anastomosed using an albumin stent and diode laser in vitro. The albumin stent provided precise apposition for an end to end anastomosis and enhanced welding strength. The anastomosis seam was lasered with an 810 nm diode laser using continuous wave and pulse light through a hand-held 600 μm noncontact optical fiber. Tensile strength, burst pressures, operative times, total...

متن کامل

Laser-assisted vascular end to end anastomosis of elastin heterograft to carotid artery with an albumin stent: a preliminary in vivo study.

BACKGROUND AND OBJECTIVES Laser-assisted end to end vascular anastomosis of an elastin heterograft to native artery may prevent problems associated with currently available vascular synthetic grafts and conventional suture anastomosis. STUDY DESIGN/MATERIALS AND METHODS A total of 21 anastomoses in the carotid arteries of 7 domestic swine were performed with an 800 nm laser and an albumin ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2002