Temporal variability of asymptomatic embolization in carotid artery stenosis and optimal recording protocols.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Although asymptomatic embolization can be detected in patients with carotid artery stenosis, its temporal variability is unclear. An understanding of this is important in designing optimal recording protocols for future prospective studies of the predictive value of embolic signals (ES). We determined the effect of repeating and extending recording times in patients with symptomatic and asymptomatic carotid stenosis. METHODS In 20 asymptomatic and 20 symptomatic subjects with > 60% carotid stenosis, we used transcranial Doppler ultrasound to record for ES in the ipsilateral middle cerebral artery. Three 1-hour recordings were performed on three separate days, and on one occasion (not necessarily the first) the recording was extended to 2 hours. The recordings were saved onto digital tape for subsequent blinded analysis. RESULTS Marked temporal variability was seen in symptomatic patients in whom the cumulative proportion of subjects with ES increased from 10 (50%) after a single hour of recording to 12 (60%) and 15 (75%) after two and three recordings, respectively. Extending the recording to 2 hours increased the yield of ES-positive patients from 6 (30%) to 8 (40%). In symptomatic patients there was excellent agreement between whether patients were positive for ES during each of two consecutive 1-hour recordings (kappa = 0.78, P = 0.0003) but poor agreement between the results of two single-hour recordings performed on different days (kappa = 0.22, P = 0.27). In asymptomatic patients, 4 (20%) were ES positive during the first hour; this increased to 5 (25%) after the recording was repeated once, with no further increase after the third recording. Extending the recording to 2 hours increased the yield from 3 (15%) to 7 (35%). In contrast to symptomatic stenoses, in patients with asymptomatic stenoses there was fair agreement between whether patients were ES positive on two consecutive 1-hour recordings (kappa = 0.49, P = 0.01) or two single-hour recordings performed on different days (kappa = 0.48, P = 0.02). Symptomatic subjects were more likely to have ES (when all 1-hour recordings were considered, 24/60 versus 10/60; P = 0.0046). ES in symptomatic subjects had a higher relative intensity increase than in asymptomatic subjects (P = 0.01). CONCLUSIONS The temporal variability of ES needs to be taken into account in the design of optimal recording protocols and comparisons of results from different studies. Extending the duration of recording beyond an hour in symptomatic stenoses is of less value, but repeating the recording on a different day will often identify additional subjects with ES. In intervention studies in symptomatic patients, the time since last symptoms must be considered. In asymptomatic stenosis, extending the duration of recording beyond an hour will increase the proportion of patients positive for ES.
منابع مشابه
Ambulatory transcranial Doppler cerebral embolic signal detection in symptomatic and asymptomatic carotid stenosis.
BACKGROUND AND PURPOSE Transcranial Doppler (TCD) ultrasound can detect asymptomatic emboli in carotid stenosis. Current systems are nonportable and can only record for short durations. A novel ambulatory TCD system allows prolonged recording. We applied this to patients with symptomatic and asymptomatic carotid stenosis to determine patterns of embolization in the 2 conditions and optimal reco...
متن کاملLong-term ambulatory monitoring for cerebral emboli using transcranial Doppler ultrasound.
BACKGROUND AND PURPOSE Transcranial Doppler (TCD) monitoring for asymptomatic cerebral emboli is currently limited to short recordings by equipment size, restricting its clinical usefulness. We have developed a first ambulatory TCD system, evaluated it in at-risk patient groups, and used it to study the pattern of embolization in patients with symptomatic carotid stenosis. METHODS The system ...
متن کاملANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملCandida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas
Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...
متن کاملAsymptomatic Embolization Predicts Stroke and TIA Risk in Patients With Carotid Artery Stenosis
Background and Purpose—Improved methods of identifying patients at high risk of thromboembolism would allow improved targeting of therapy. One such situation is carotid artery stenosis. This is associated with an increased risk of stroke, which can be reduced by carotid endarterectomy. However, the risk-benefit ratio is low in patients with tight asymptomatic stenosis and moderate symptomatic s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 29 6 شماره
صفحات -
تاریخ انتشار 1998