Optimization of the separation and on-line sample concentration of phenethylamine designer drugs with capillary electrophoresis-fluorescence detection.

نویسندگان

  • Chung-Chen Tsai
  • Ju-Tsung Liu
  • You-Ren Shu
  • Po-Han Chan
  • Cheng-Huang Lin
چکیده

Five 2C-series of phenethylamine designer drugs, including 2,5-dimethoxy-4-ethylthio-phenethylamine (2C-T-2), 2,5-dimethoxy-4-(n)-propylthiophenethylamine (2C-T-7), 4-chloro-2,5-dimethoxyphenethylamine (2C-C), 4-bromo-2,5-dimethoxy-phenethylamine (2C-B), 2,5-dimethoxy-4-iodo-phenethylamine (2C-I), were synthesized and standard GC/MS and fluorescence spectra are reported for them. A mixture of the five drugs was separated and detected by means of capillary electrophoresis (CE) with native fluorescence and light emitting diode (LED)-induced fluorescence (LIF) detection, respectively, for comparison. In the former case, exciting at a wavelength of 300 nm from a Xe lamp was used. The detection limits were found to be only in the range of approximately 10(-4) M by the micellar electrokinetic chromatography (MEKC) mode but were improved to approximately 10(-7) M when the sweeping-MEKC mode was used. For a highly sensitive analysis, LED-induced fluorescence detection was examined by derivatizing the compounds with a fluorescent dye, fluorescein isothiocyanate isomer I (FITC). A blue-LED (approximately 2 mW) was used as the fluorescence excitation source. The detection limits were improved to approximately 10(-7) and approximately 10(-8) M, respectively, when the MEKC and stacking-MEKC modes were applied. A mimic urine sample was obtained by spiking urine from a volunteer with the five standards, and after liquid-liquid extraction, the sample was examined by means of the MEKC-LIF mode. The extraction procedures used for the urine sample and the CE conditions for the separation were optimized.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

A microwave-assisted fluorescent labeling method for the separation and detection of amphetamine-like designer drugs by capillary electrophoresis.

A microwave-assisted fluorescence labeling method for use in CE-LIF (capillary electrophoresis-laser induced fluorescence) is described. Six amphetamine-like designer drugs, namely, o-, m-, p-chloro- and o-, m-, p-fluoro-amphetamine derivatives, were synthesized and used as model compounds. FITC (fluorescein isothiocyanate isomer I) and a blue-laser were used as the fluorescent labeling reagent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1101 1-2  شماره 

صفحات  -

تاریخ انتشار 2006