Local lymph node assay: how testing laboratories apply OECD TG 429 for REACH purposes.

نویسنده

  • Costanza Rovida
چکیده

The Local Lymph Node Assay (LLNA) is the official method for assessing the allergic contact dermatitis potential of chemicals for the purposes of REACH regulation. The LLNA went through a validation process that allowed the delineation of a robust protocol for performing new tests. The OECD accepted this method in 2002 and published OECD TG 429. The European Chemical Agency (ECHA) recently published data that were submitted in the registration dossiers of chemicals. This database was analysed to determine how testing laboratories apply OECD TG 429. This analysis comes after a detailed analysis of four full study reports that were also prepared for REACH purposes. Although the majority of the tests are fully compliant with OECD TG 429, some showed major deviations, and a number of others used more animals than necessary. This suggests that in vivo tests need to be planned more carefully and consciously to obtain meaningful results with the minimum animal number necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

For Skin sensitisation test method site: Skin sensitisation TITLE OF THE TEST GUIDELINES (YEAR OF APPROVAL): In Chemico Skin Sensitisation: Direct Peptide Reactivity Assay (DPRA), OECD 442C

TITLE OF THE TEST GUIDELINES (YEAR OF APPROVAL): In Chemico Skin Sensitisation: Direct Peptide Reactivity Assay (DPRA), OECD 442C (adopted 2015) In Vitro Skin Sensitisation: ARE-Nrf2 Luciferase Test Method, OECD 442D (adopted 2015) In Vitro Skin Sensitisation: Human Cell Line Activation Test (h-CLAT) (draft OECD TG under discussion, EURL ECVAM recommendation published 2015) In vivo tests: Skin ...

متن کامل

Comparison of BALB/c and CBA/J mice for the local lymph node assay using bromodeoxyuridine with flow cytometry (LLNA: BrdU-FCM).

The local lymph node assay using 5-bromo-2-deoxyuridine (BrdU) with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA that is used to identify skin sensitizers by counting BrdU-incorporated lymph node cells (LNCs) with flow cytometry. Unlike other LLNA methods (OECD TG 429, 442A and 442B) in which the CBA/J mouse strain is used, LLNA: BrdU-FCM was originally designed to be compatible with BALB...

متن کامل

Oecd Guideline for the Testing of Chemicals

1. The OECD Test Guideline Programme periodically reviews progress in test method development and refinement, both in terms of scientific advances and animal welfare, to determine whether existing Test Guidelines should be updated and whether new Guidelines should be developed. Toward that end, a new assay for the determination of skin sensitisation in the mouse, the Local Lymph Node Assay (LLN...

متن کامل

In vitro differentiation of skin sensitizers by cell signaling pathways.

Animal testing causes ethical problems and in view of EU regulations (e.g. EU-Guideline (76/768/EEC, February 2003)) or REACH the development of reliable in vitro assays has become even more important. Up to now, we use the modified local lymph node assay (IMDS) for toxicological hazard identification of sensitizing and irritant properties of chemicals in accordance with OECD Guideline 429. In ...

متن کامل

Appraisal of within- and between-laboratory reproducibility of non-radioisotopic local lymph node assay using flow cytometry, LLNA:BrdU-FCM: comparison of OECD TG429 performance standard and statistical evaluation.

Mouse local lymph node assay (LLNA, OECD TG429) is an alternative test replacing conventional guinea pig tests (OECD TG406) for the skin sensitization test but the use of a radioisotopic agent, (3)H-thymidine, deters its active dissemination. New non-radioisotopic LLNA, LLNA:BrdU-FCM employs a non-radioisotopic analog, 5-bromo-2'-deoxyuridine (BrdU) and flow cytometry. For an analogous method, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ALTEX

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2011