[Simultaneous noninvasive monitoring for radial forearm and fibula flaps using laser Doppler flowmetry and tissue spectrophotometry].

نویسندگان

  • F Hölzle
  • A Rau
  • S Swaid
  • D J Loeffelbein
  • D Nolte
  • K-D Wolff
چکیده

AIM In the literature currently available monitoring devices are usually divided into two major groups: those for monitoring perfusion and those for measuring tissue oxygenation. The O(2)C (oxygen to see) system combines these two ways of monitoring free flap viability. The aim of this prospective study was to determine the necessity of flap revision and when unnecessary revision can be avoided. Another point of interest was the question of whether critical values for the successful course of free flaps could be defined and in addition whether such values would differ for different flap types. PATIENTS AND METHODS In a prospective study 82 free flaps (61 radial forearm flaps and 21 fibula flaps) were monitored with the O(2)C monitoring unit. Measurements were carried out intraoperatively and postoperatively up to 14 days. RESULTS Perfusion compromise occurred in 12 (14.6%) of 82 monitored free flaps. Operative exploration was performed in seven cases, in five of them successfully. Five flaps (three radial forearm and two fibula flaps) were lost due to vascular compromise, which led to an overall success rate of 93.4%. Venous congestion was identified by a rapid increase in hemoglobin concentration of more than 30%. An abrupt decline of blood flow and hemoglobin oxygenation indicated arterial occlusion. Vascular complications were detected in all cases prior to clinical assessment with no false positive or negative results. For radial forearm flaps a hemoglobin oxygenation of 15%, a superficial flow of 10 AU, and a deep flow of 20 AU were identified as minimum values for flap viability. For fibula flaps a hemoglobin oxygenation of 10%, a superficial flow of 5 AU, and a deep flow of 15 AU were determined as minimum values. CONCLUSION O(2)C combines laser Doppler flowmetry and tissue spectrophotometry and for the first time allows simultaneous measurement of the microcirculatory parameters including blood flow, flow velocity, hemoglobin concentration, and hemoglobin oxygenation. We found this new noninvasive technique to be a reliable and accurate method for evaluating flap viability and improving the success rate in free flap transfer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry.

The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1....

متن کامل

Functional outcomes of fibula and osteocutaneous forearm free flap reconstruction for segmental mandibular defects.

OBJECTIVE/HYPOTHESIS To demonstrate that the osteocutaneous radial forearm free flap provides equivalent functional outcomes and improved morbidity compared to the fibular free flap in mandibular reconstruction. STUDY DESIGN Retrospective review. METHODS There were 168 patients requiring free flap reconstruction of segmental mandibular defects between January 2001 and December 2008. Mean fo...

متن کامل

The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction.

OBJECTIVE To determine if the implantable Cook-Swartz Doppler Flow Monitoring System (Cook Vascular Inc, Vandergrift, Pennsylvania) improves surgical salvage rates for compromised free flaps. DESIGN Retrospective medical record review spanning 2002 to 2006 for a large head and neck oncology program. SETTING A tertiary care hospital. PATIENTS A consecutive series of 351 patients (244 men a...

متن کامل

Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry

Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome  by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...

متن کامل

Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging.

BACKGROUND In microsurgery, there is a demand for more reliable methods of post-operative monitoring of free flaps, especially with regard to tissue-threatening obstructions of the feeding arteries and draining veins. In this study, we evaluated laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) to assess their possibilities to detect partial and full venous outflow obstruc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Mund-, Kiefer- und Gesichtschirurgie : MKG

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2005