The influence of high-frequency jet ventilation with varying cardiac-cycle specific synchronization on cardiac output in ARDS.

نویسندگان

  • D C Angus
  • N M Lidsky
  • L M Dotterweich
  • M R Pinsky
چکیده

BACKGROUND Previous studies have shown "beat-to-beat" variation in systemic BP with high-frequency jet ventilation (HFJV). However, it is not clear if such changes are paralleled by changes in cardiac output. OBJECTIVE To characterize the effect of HFJV near or equal to the heart rate (HR) on beat-to-beat cardiac output in an adult human subject with ARDS. DESIGN Case study. SETTING ICU, university teaching hospital. PATIENTS One patient with end-stage liver disease complicated by sepsis, severe pancreatitis, ARDS, and multisystem organ failure. METHODS The patient was intubated, sedated, paralyzed, and ventilated with controlled mechanical ventilation (CMV). Ventilatory mode was then switched to HFJV at fixed frequencies (f) near but not equal to the HR (f= 100, 110, and 120 beats/min; HR=108/min). HFJV was then synchronized to the ECG such that f and HR were equal. Continuous cardiac output (COc) was monitored during change of ventilator mode from CMV to fixed-rate HFJV to synchronized HFJV, then followed through progressive delays in jet triggering within the cardiac cycle during the synchronous HFJV mode. COc was monitored by arterial pulse-contour analysis, allowing assessment of beat-to-beat changes in cardiac output. MEASUREMENTS AND MAIN RESULTS A cyclic variation in COc equal to the beat frequency difference between f and HR was observed (harmonic interaction) during fixed-rate HFJV. This COc oscillation was abolished during synchronous HFJV. COc was significantly greater during systolic synchronous HFJV as compared to diastolic synchronous HFJV or fixed-rate HFJV (10.1 to 9.0 [p<0.05] and to 8.6 [p<0.05] L/min, systolic synchronous to diastolic synchronous and to fixed-rate HFJV, respectively). CONCLUSIONS This study demonstrates instantaneous variations in cardiac output in a human subject with fixed rates of HFJV near to the HR in humans. These variations are abolished by synchronous HFJV but cardiac output was dependent on the timing of the HFJV inspiration in relation to the cardiac cycle. COc is a potentially valuable method to monitor sudden changes in cardiac output and facilitate attempts to maximize cardiac output during synchronized HFJV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-frequency oscillatory ventilation for adult respiratory distress syndrome--a pilot study.

OBJECTIVE To evaluate the safety and effectiveness of high-frequency oscillatory ventilation using a protocol designed to recruit and maintain optimal lung volume in patients with severe adult respiratory distress syndrome (ARDS). SETTING Surgical and medical intensive care units in a tertiary care, military teaching hospital. DESIGN A prospective, clinical study. PATIENTS Seventeen patie...

متن کامل

High frequency jet ventilation and aspirin poisoning.

ASPIRIN poisoning is responsible for over 200 deaths per annum in England and Wales. Forced alkaline diuresis is advocated to hasten renal elimination of the drug when plasma salicylate levels exceed 500 mg/l, whilst charcoal haemoperfusion is the treatment of choice when plasma salicylate levels exceed 900 mg/kg.' This severity of poisoning causes gross respiratory, metabolic and coagulation d...

متن کامل

Cardiac index and oxygen delivery during low and high tidal volume ventilation strategies in patients with acute respiratory distress syndrome: a crossover randomized clinical trial

INTRODUCTION The beneficial effect of low tidal volume (TV) ventilation strategy on mortality in patients with acute respiratory distress syndrome (ARDS) has been attributed to the protective effect on ventilator-induced lung injury, and yet its effect on cardiovascular function might also play an important role. The aim of this study was to assess whether low TV ventilation improves cardiac ou...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 112 6  شماره 

صفحات  -

تاریخ انتشار 1997