Treatment Planning for Self-Shielded Radiosurgery

نویسندگان

  • John R. Adler
  • Achim Schweikard
  • Younes Achkire
  • Oliver Blanck
  • Mohan Bodduluri
  • Lijun Ma
  • Hui Zhang
چکیده

A five degree of freedom, robotic, radiosurgical system dedicated to the brain is currently under development. In the proposed design, the machine is entirely self-shielded. The main advantage of a self-shielded system is the simplification of the system's installation, which can reduce the cost of radiosurgery. In this way, more patients can benefit from this minimally invasive and highly effective type of procedure. For technical reasons, space inside the shielded region is limited, which leads to constraints on the design. Here, two axes of rotation move a 3-megavolt linear accelerator around the patient's head at a source axis distance of 400 millimeters (mm), while the integrated patient table is characterized by two additional rotational, and one translational, degrees of freedom. Eight cone collimators of different diameters are available. The system can change the collimator automatically during treatment, using a collimator wheel. Since the linear accelerator can only move with two rotational axes, it is not possible to reposition the beam translationally (as it is in six degrees of freedom robotic radiosurgery). To achieve translational repositioning, it is necessary to move the patient couch. Thus, translational repositioning must be kept to a minimum during treatment. Our goal in this contribution is a preliminary investigation of dose distributions attainable with this type of design. Thus, we do not intend to design and evaluate the treatment planning system itself, but rather to establish that appropriate dose distributions can be achieved with this design under realistic clinical circumstances. Our simulation suggests that dose gradients and conformity for complex target shapes, corresponding to state-of-the-art systems, can be achieved with this construction, although a detailed evaluation of the system itself would be needed in the future.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Shielding Analysis of the Zap-X System

The Zap-X is a self-contained and first-of-its-kind self-shielded therapeutic radiation device dedicated to brain as well as head and neck stereotactic radiosurgery (SRS). By utilizing an S-band linear accelerator (linac) with a 2.7 megavolt (MV) accelerating potential and incorporating radiation-shielded mechanical structures, the Zap-X does not typically require a radiation bunker, thereby sa...

متن کامل

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.

PURPOSE To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. METHODS The PSD consists of a 1 mm diameter by 1 mm long sc...

متن کامل

Clinical implementation of an automated planning system for gamma knife radiosurgery.

PURPOSE To evaluate an automated treatment planning system for gamma knife radiosurgery. This planning system was developed in our clinic and is now in routine clinical use. The system simultaneously optimizes the shot sizes, locations, and weights. It also guides the user in selecting the total number of radiation shots. METHODS AND MATERIALS We assessed the clinical significance of the auto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017