Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay

نویسندگان

  • Tomoaki Kozaki
  • Soomin Lee
  • Takayuki Nishimura
  • Tetsuo Katsuura
  • Akira Yasukouchi
چکیده

BACKGROUND Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO). In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. METHODS Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). The melatonin levels were analyzed in duplicate using commercially available ELISA kits. RESULTS The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL). The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level (<6 pg/mL), although the BA plots didn't show proportional and relative biases, there was no significant correlation between passive and cotton saliva collection samples. CONCLUSION Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of an enzyme-linked immunosorbent assay developed for measuring cortisol concentration in human saliva and serum for its applicability to analyze cortisol in pig saliva

BACKGROUND The purpose of this study was to validate a commercially available enzyme-linked immunosorbent assay (ELISA) developed for measuring free cortisol in human saliva and total cortisol concentration in diluted human serum, for its applicability in measuring cortisol concentration in pig saliva. Collection of saliva is less stressful than e.g. blood sampling, and is a non-invasive method...

متن کامل

Validation of salivary oxytocin and vasopressin as biomarkers in domestic dogs.

BACKGROUND Oxytocin (OT) and Vasopressin (AVP) are phylogenetically conserved neuropeptides with effects on social behavior, cognition and stress responses. Although OT and AVP are most commonly measured in blood, urine and cerebrospinal fluid (CSF), these approaches present an array of challenges including concerns related to the invasiveness of sample collection, the potential for matrix inte...

متن کامل

Detection of Chlamydia trachomatis in genital specimens by the Chlamydiazyme test.

Cotton swabs were used to collect two specimens each from 416 patients (206 males, 210 females) attending a sexually transmitted disease clinic. The first swab was transported in Specimen Storage Reagent and extracted in Specimen Dilution Buffer for enzyme immunoassay by Chlamydiazyme (Abbott Laboratories); the second swab was extracted into 2SP and inoculated into McCoy cell cultures. In the f...

متن کامل

Prolonged Sleep Deprivation and Continuous Exercise: Effects on Melatonin, Tympanic Temperature, and Cognitive Function

The purpose of this study was to examine tympanic temperature, melatonin, and cognitive function during a 36-hour endurance event. Nine male and three female participants took part in a 36-hour sustained endurance event without sleep (N = 12, mean age = 31.8 ± 5.0 yrs). Participants were stopped for data collection at checkpoints throughout the 36-hour event. Tympanic temperature was assessed, ...

متن کامل

Measuring physiological stress in the common marmoset (Callithrix jacchus): Validation of a salivary cortisol collection and assay technique

Cortisol levels are often used as a physiological measure of the stress response in captive primates, with non-invasive measures of this being an important step in welfare assessment. We report a method of collecting saliva samples voluntarily from unrestrained captive common marmosets (Callithrix jacchus), and validate an enzyme-linked immunosorbent assay (ELISA) technique previously unused in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2011