Performance of a Low-Background High Purity Germanium Detector with a Novel EndCap

نویسندگان

  • Ronald M. Keyser
  • Timothy R. Twomey
  • David Gunter
چکیده

Low background HPGe detectors have been used for many years in the measurement of low activities of radionuclides in various materials. With the increased importance of nuclear forensics, low background detectors are in increasing demand. The endcap and other materials used in low background detector construction must be selected to have the lowest activity possible. In some cases, the materials with the lowest amounts of naturally occurring radionuclides are difficult to obtain and costly. To obtain the best efficiency at all energies, low atomic number materials are needed for the endcap to ensure maximum transmission. Aluminum and magnesium are the materials used most often, with beryllium and carbon fiber being used for the low energy entrance windows. Even specially selected aluminum, magnesium and beryllium contain measurable amounts of naturally occurring radiomaterials, and beryllium has an associated health hazard. In a new approach, a new endcap has been designed completely from carbon fiber materials. This material is not mined so it does not contain any naturally occurring radionuclides. It has a low average atomic number, resulting in good transmission of low energy photons. The transmission of entrance windows below 60 keV is further improved because no support material for the entrance window itself is required. The efficiency of a large diameter and length detector with the new endcap has been measured and shows improvement over conventional endcaps for extended geometry samples. The uniformity of the sensitivity for low energies has been measured. The low background spectrum has been measured and is compared to conventional low background endcap

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LArGe: Background suppression using liquid argon (LAr) scintillation for 0νββ decay search with enriched germanium (Ge) detectors

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK-Heidelberg are reported. The liquid argon–germanium system (LArGe) is operated as a 4π anti-Compton spectrometer to suppress backgrounds in the HPGe. This R&D is carried out in the framework of the Gerda experiment which searches for 0νββ decays with HPGe det...

متن کامل

Low Energy Neutrino Physics at the Kuo-Sheng Reactor Neutrino Laboratory in Taiwan

A laboratory has been constructed by the TEXONO Collaboration at the Kuo-Sheng Reactor Power Plant in Taiwan to study low energy neutrino physics. The facilities of the laboratory are described. A limit on the neutrino magnetic moment of μν̄e < 1.3× 10 −10 μB at 90% confidence level has been achieved from measurements with a high-purity germanium detector. Other physics topics, as well as the va...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Design and Construction of an Ultra-low-background 14 Germanium Crystal Array for High Efficiency and Coincidence Measurements

Physics experiments, environmental surveillance, and treaty verification techniques continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be done by detecting a greater fraction of gamma emissions from a sample (higher detection efficiency) and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gam...

متن کامل

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006