Frequency and amplitude modulation have different effects on the percepts elicited by retinal stimulation.

نویسندگان

  • Devyani Nanduri
  • Ione Fine
  • Alan Horsager
  • Geoffrey M Boynton
  • Mark S Humayun
  • Robert J Greenberg
  • James D Weiland
چکیده

PURPOSE In an effort to restore functional form vision, epiretinal prostheses that elicit percepts by directly stimulating remaining retinal circuitry were implanted in human subjects with advanced retinitis pigmentosa RP). In this study, manipulating pulse train frequency and amplitude had different effects on the size and brightness of phosphene appearance. METHODS Experiments were performed on a single subject with severe RP (implanted with a 16-channel epiretinal prosthesis in 2004) on nine individual electrodes. Psychophysical techniques were used to measure both the brightness and size of phosphenes when the biphasic pulse train was varied by either modulating the current amplitude (with constant frequency) or the stimulating frequency (with constant current amplitude). RESULTS Increasing stimulation frequency always increased brightness, while having a smaller effect on the size of elicited phosphenes. In contrast, increasing stimulation amplitude generally increased both the size and brightness of phosphenes. These experimental findings can be explained by using a simple computational model based on previous psychophysical work and the expected spatial spread of current from a disc electrode. CONCLUSIONS Given that amplitude and frequency have separable effects on percept size, these findings suggest that frequency modulation improves the encoding of a wide range of brightness levels without a loss of spatial resolution. Future retinal prosthesis designs could benefit from having the flexibility to manipulate pulse train amplitude and frequency independently (clinicaltrials.gov number, NCT00279500).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quadrature Amplitude Modulation All Optical Orthogonal Frequency Division Multiplexing-dense Wavelength Division Multiplexing-optical Wireless Communication System under Different Weather Conditions

This paper proposes an analytical model for evaluating the performance of dense wavelength division multiplexing (DWDM) for all optical orthogonal frequency division multiplexing (AO-OFDM) optical wireless channel. The investigated performance for proposed system is evaluated for the parameters  bit error rate (BER) and Q factor .The constellation diagrams, and bit error rate (BER) of the recei...

متن کامل

Responses to pulsatile subretinal electric stimulation: effects of amplitude and duration.

In working to improve the quality of visual percepts elicited by retinal prosthetics, considerable effort has been made to understand how retinal neurons respond to electric stimulation. Whereas responses arising from direct activation of retinal ganglion cells have been well studied, responses arising through indirect activation (e.g., secondary to activation of bipolar cells) are not as well ...

متن کامل

Spatial resolution and perception of patterns mediated by a subretinal 16-electrode array in patients blinded by hereditary retinal dystrophies.

PURPOSE The perception of 11 persons blinded by hereditary retinal degeneration elicited by a subretinally implanted 16-electrode array used for light-independent direct stimulation of the retina is described. This device is part of the Tübingen retina implant, which also employs a light-sensitive, multiphotodiode array (MPDA). The ability to reliably recognize complex spatial percepts was inve...

متن کامل

Stimulation with a wireless intraocular epiretinal implant elicits visual percepts in blind humans.

PURPOSE Electrical stimulation of retinal neurons has been shown to be a feasible way to elicit visual percepts in patients blind from retinal degenerations. The EPIRET3 retinal implant is the first completely wireless intraocular implant for epiretinal stimulation. Stimulation tests have been performed during a clinical trial that was carried out at the eye clinics of Aachen and Essen to evalu...

متن کامل

Responses to pulsatile subretinal electric stimulation : effects of 2 amplitude and duration

29 30 In working to improve the quality of visual percepts elicited by retinal prosthetics, considerable 31 effort has been made to understand how retinal neurons respond to electric stimulation. While 32 responses arising from direct activation of retinal ganglion cells have been well studied, 33 responses arising through indirect activation (e.g. secondary to activation of bipolar cells), are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2012