Multidetector CT dose: clinical practice improvement strategies from a successful optimization program.
نویسندگان
چکیده
PURPOSE The aims of this study were to collect data relating to radiation dose delivered by multidetector CT scanning at 10 hospitals and private practices in Queensland, Australia, and to test methods for dose optimization training, including audit feedback and didactic, face-to-face, small-group teaching of optimization techniques. METHODS Ten hospital-based public and private sector radiology practices, with one CT scanner per site, volunteered for the project. Data were collected for a variety of common adult and pediatric CT scanning protocols, including tube current-time product, pitch, collimation, tube voltage, the use of dose modulation, and scan length. A one-day feedback and optimization training workshop was conducted for participating practices and was attended by the radiologist and medical imaging technologist responsible for the project at each site. Data were deidentified for the workshop presentation. During the feedback workshop, a detailed analysis and discussion of factors contributing to dose for higher dosing practices for each protocol occurred. The postoptimization training data collection phase allowed changes to median and spread of doses to be measured. RESULTS During the baseline survey period, data for 1,208 scans were collected, and data from 1,153 scans were collected for the postoptimization dose survey for the 4 adult protocols (noncontrast brain CT, CT pulmonary angiography , CT lumbar spine, and CT urography). A mean decrease in effective dose was achieved with all scan protocols. Average reductions of 46% for brain CT, 28% for CT pulmonary angiography, 29% for CT lumbar spine, and 24% CT urography were calculated. It proved impossible to collect valid pediatric data from most sites, because of the small numbers of children presenting for multidetector CT, and phantom data were acquired during the preoptimization and postoptimization phase. Substantial phantom dose reductions were demonstrated at all sites. CONCLUSION Audit feedback and small-group teaching about optimization enabled clinically meaningful dose reduction for a variety of common adult scans. However, access to medical radiation physicists, assistance with time-consuming data collection, and technical support from a medical imaging technologist were costly and critical to the success of the program.
منابع مشابه
Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand
Correspondence Dr. Jakob Neubauer Radiology, University Medical Center Freiburg Hugstetterstr. 55 79106 Freiburg Germany Tel.: ++ 49/7 61/3 8262 Fax: ++ 49/7 61/3 8300 [email protected] Abstract ▼ Purpose: Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Materials and Methods: Dose ca...
متن کاملSCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.
Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of th...
متن کاملCharacterisation of hepatobiliary lesions in an African referral hospital: initial MDCT dose challenges
Methods A crossectional survey was carried out on 69 patients who underwent triple phase CT imaging for suspected hepatobiliary neoplastic involvement at a referral hospital in Kenya that had acquired its first multidetector CT scan (16 slice) between July 2008 and March 2009. Justification of examination (matching clinical indications and imaging findings), optimisation of scanning parameters ...
متن کاملRadiation dose-reduction strategies for neuroradiology CT protocols.
Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places i...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Radiology : JACR
دوره 7 8 شماره
صفحات -
تاریخ انتشار 2010