Charged-particle tracking with high spatial and temporal resolution using capillary arrays filled with liquid scintillator
نویسندگان
چکیده
We have developed a new technique that allows the trajectories of ionizing particles to be imaged with very high spatial and temporal resolution. This technique, developed for future experiments in high-energy physics, may also be applied in other fields. Central to the technique is a detector consisting of a bundle of thin, glass capillaries filled with a liquid scintillator of high refractive index. These liquid-core scintillating fibres act simultaneously as a detector of charged particles and as an image guide. Track images seen at the readout end of the capillary bundle are amplified by an optoelectronic chain consisting of a set of image-intensifier tubes and read by a photosensitive CCD camera. We report here on results obtained with detector prototypes. A spatial resolution of 6—14 m, dependent on image magnification prior to readout, has been obtained with 16 pm capillaries. The high scintillation efficiency of the liquid scintillator used and a large light attenuation length —.'3 m for 20 pm capillaries — result in hit densities along the track of a minimumionizing particle of 8.5 mm' and 3.5 mm1 at distances from the readout window of s2 cm and m respectively. The radiation resistance of the detector is an order of magnitude greater than that of other types of tracking device of comparable performance. To complement the detector we have been developing a new readout system based around a gateable Vacuum Image Pipeline (VIP) and an Electron-Bombarded CCD camera. These increase the spatial and temporal resolution obtained with the detector and render it particularly attractive as a microvertex detector for the observation of short-lived particles in high-energy physics experiments performed with elevated interaction rates.
منابع مشابه
Amorphous Silicon Flat Panel Imagers for Medical Application
A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...
متن کاملFusion of LST products of ASTER and MODIS Sensors Using STDFA Model
Land Surface Temperature (LST) is one of the most important physical and climatological crucial yet variable parameter in environmental phenomena studies such as, soil moisture conditions, urban heat island, vegetation health, fire risk for forest areas and heats effects on human’s health. These studies need to land surface temperature with high spatial and temporal resolution. Remote sensing ...
متن کامل100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neutron imaging. In order to partially overcome the neutron intensity problem for the high temporal ...
متن کاملA performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation
PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets. experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the ...
متن کاملDiscrete Scintillator Coupled Mercuric Iodide Photodetector Arrays for Breast Imaging
Multi-element (4x4) imaging arrays with high resolution collimators, size matched to discrete CsI(T1) scintillator arrays and mercuric iodide photodetector arrays (HgI, PDA) are under development as prototypes for larger 16x16 element arrays. The compact nature of the arrays allows detector positioning in proximity to the breast to eliminate activity not in the lineof-sight 0; the collimator, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004