Design of a Swept-Source, Anatomical OCT System for Pediatric Bronchoscopy.
نویسندگان
چکیده
We describe the design and performance of a long coherence length, swept-source anatomical OCT (aOCT) system for pediatric airway imaging. A fiber-optic catheter is designed to be accommodated by a small-bore bronchoscope, and is scanned distally in a helical scan pattern to provide aOCT during bronchoscopy. We discuss particular challenges associated with the need for large imaging range, low SNR roll-off, and small catheter diameter. We present 3-D visualizations of airway phantoms and discuss optimization of the airway surface geometry obtained by aOCT. Accurate reconstruction of airway geometry will enable predictive modeling of patients suffering from airway obstruction.
منابع مشابه
Ultra-compact silicon photonic integrated interferometer for swept-source optical coherence tomography.
We demonstrate an ultra-compact silicon integrated photonic interferometer for swept-source optical coherence tomography (SS-OCT). The footprint of the integrated interferometer is only 0.75×5 mm2. The design consists of three 2×2 splitters, a 13 cm physical length (50.4 cm optical length) reference arm, and grating couplers. The photonic integrated circuit was used as the interferometer of an...
متن کاملSensitivity advantage of swept source and Fourier domain optical coherence tomography.
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source (SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Exper...
متن کاملIn vivo imaging of the rodent eye with swept source/Fourier domain OCT
Swept source/Fourier domain OCT is demonstrated for in vivo imaging of the rodent eye. Using commercial swept laser technology, we developed a prototype OCT imaging system for small animal ocular imaging operating in the 1050 nm wavelength range at an axial scan rate of 100 kHz with ~6 µm axial resolution. The high imaging speed enables volumetric imaging with high axial scan densities, measuri...
متن کاملNoninvasive Visualization and Analysis of the Human Parafoveal Capillary Network Using Swept Source OCT Optical Microangiography.
PURPOSE We characterized the foveal avascular zone (FAZ) and the parafoveal capillary network in healthy subjects using swept source OCT optical microangiography (OMAG). METHODS We acquired OMAG images of the macula of 19 eyes (13 healthy individuals) using a prototype swept source laser OCT. En face images of the retinal vasculature were generated for superficial and deep inner retinal layer...
متن کاملMacular choroidal thickness in normal pediatric population measured by swept-source optical coherence tomography.
PURPOSE To evaluate choroidal thickness in healthy pediatric population by swept-source longer-wavelength optical coherence tomography (SS-OCT). METHODS This was a cross-sectional comparative, noninterventional study. The macular area of 83 eyes from 43 pediatric patients (<18 years) was studied with an SS-OCT prototype system. Macular choroidal thickness was manually determined at 750-μm int...
متن کاملذخیره در منابع من