Prediction of Egyptian 500 kV Overhead Transmission lines Radio- Interference by Using the Excitation Function

نویسنده

  • ADEL Z. EL DEIN
چکیده

This paper presents applications of the excitation function on the prediction of the RadioInterference (RI) of overhead transmission line, due to corona effect. These applications are done under different weather conditions such as: heavy rain, wet conductor and fair weather. Also, this paper investigates the factors influencing the RI level namely; the height of conductors, phase spacing, number of subconductors in the bundle, diameter of subconductor and subconductor spacing in the bundle. In this paper, it is shown that the RI level is dependent on the weather conditions. Where, the RI level under heavy rain has the maximum level, hence, it should be considered as a basic level of any overhead transmission line (OHTL). Key-Words: Corona, Excitation function, Radio interference, Overhead transmission line

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Magnetic Field Produced by OHTL under Normal and Abnormal Conditions

Ground level magnetic field from overhead transmission lines (OHTLs) is of increasingly important considerations in several research areas due to their harmful effect on human health and environment. This paper computes the ground level magnetic field, under normal and abnormal conditions of Egyptian 500-kV single circuit transmission line, in three dimension (3-D) coordinates by using 3-D inte...

متن کامل

The Effects of the Span Configurations and Conductor Sag on the Magnetic - Field Distribution under Overhead Transmission

Copyright 1996-2012 Researchpub.org. All rights Reserved. 11 Abstract— Ground level electric and magnetic-fields from overhead power transmission lines are of increasingly important considerations in several research areas due to their impact on health and environmental issues. The paper presents a more generalized technique to calculate the magnetic-field generated by power transmission lines...

متن کامل

Conductor Corona Noise Prediction on High Voltage Ac Lines

The conductor corona noise of four local 400 kV AC transmission lines is measured and compared to predictions. The prediction software developed is based on the EPRI semi-analytical approach using excitation functions and the theory of natural modes. The nature and accuracy of the prediction software is discussed along with relevant corona noise metrology issues encountered.

متن کامل

Online Voltage Stability Monitoring and Prediction by Using Support Vector Machine Considering Overcurrent Protection for Transmission Lines

In this paper, a novel method is proposed to monitor the power system voltage stability using Support Vector Machine (SVM) by implementing real-time data received from the Wide Area Measurement System (WAMS). In this study, the effects of the protection schemes on the voltage magnitude of the buses are considered while they have not been investigated in previous researches. Considering overcurr...

متن کامل

Determination of the Induced Voltages by 220 kV Electric Overhead Power Lines Working in Parallel and Narrow Routes. Measurements on the Ground and Mathematical Model

The paper presents the measurements that the author has done in the South West area of Romania for the 220 kV double circuit overhead power lines having a passive circuit and an active one. It also describes a mathematical simulation for determining the induced voltages by the active circuit into the disconnected one. The measurements are compared with those obtained through calculations in ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014