Vessel Centerline Tracking in CTA and MRA Images Using Hough Transform

نویسندگان

  • Maysa M. G. Macedo
  • Choukri Mekkaoui
  • Marcel P. Jackowski
چکیده

We proposed a semi-automated method to detect and track vessel centerlines in CTA and MRA images. During the tracking process, we analyze probable bifucation points. The methodology has shown to work well under significant amounts of noise. The main contribution of this work is the use of HT to define the seed point for tracking and detecting the vessel scale without resorting to multiscale analysis techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Initialization Algorithm for Carotid Artery Segmentation in CTA Images

Analysis of CT datasets is commonly time consuming because of the required manual interaction. We present a novel and fast automatic initialization algorithm to detect the carotid arteries providing a fully automated approach of the segmentation and centerline detection. First, the volume of interest (VOI) is estimated using a shoulder landmark. The carotid arteries are subsequently detected in...

متن کامل

Accuracy Evaluation of Different Centerline Approximations of Blood Vessels

Accurate determination of the vessel axis is a prerequisite for automated visualization and quantification of artery diseases. This paper presents an evaluation of different methods for approximating the centerline of the vessel in a phantom simulating the peripheral arteries. Six algorithms were used to determine the centerline of a synthetic peripheral arterial vessel. They are based on: ray ...

متن کامل

Multispectral MRI centerline tracking in carotid arteries

We propose a minimum cost path approach to track the centerlines of the internal and external carotid arteries in multispectral MR data. User interaction is limited to the annotation of three seed points. The cost image is based on both a measure of vessel medialness and lumen intensity similarity in two MRA image sequences: Black Blood MRA and Phase Contrast MRA. After intensity inhomogeneity ...

متن کامل

Detection of Microaneurysms in Retinal Angiography Images Using the Circular Hough Transform

This paper presents an automated method for detecting microaneurysms in the retinal angiographic images by using image processing techniques. In the presented method, in order to fade or remove the pseudo images, first retinal images are pre-processed. Then microaneurysms are identified by circular Hough transform. In the existing methods of dete...

متن کامل

Detection of Microaneurysms in Retinal Angiography Images Using the Circular Hough Transform

This paper presents an automated method for detecting microaneurysms in the retinal angiographic images by using image processing techniques. In the presented method, in order to fade or remove the pseudo images, first retinal images are pre-processed. Then microaneurysms are identified by circular Hough transform. In the existing methods of dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010