Investigation of unusual high serum indices for lipemia in clear serum samples on Siemens analysers Dimension

نویسندگان

  • Eva Fliser
  • Ksenija Jerkovič
  • Tanja Vidovič
  • Maksimiljan Gorenjak
چکیده

INTRODUCTION We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006-2010 on Siemens Dimension analyzers. MATERIALS AND METHODS In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640). RESULTS In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values <0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers. CONCLUSION A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference of serum indices in the analyzer function

Background: Analyzer has the capability to detect hemolysis, icterus, and lipemia in samples and produces semi quantitative unit less index values for hemoglobin, bilirubin, or intralipid (so-called serum indices), but these serum index functions are not intended for diagnostic purposes. With increasing amounts of the specific interfering compounds, increasing index values are generated, which ...

متن کامل

Lipemia retinalis – an unusual cause of visual acuity deterioration

BACKGROUND Hyperlipidemia is an identified factor of premature vessel atherosclerosis. Lipemia retinalis is an unusual retinal manifestation of hyperlipidemia and is thought to be directly correlated with the serum triglyceride level. CASE REPORT This paper discusses the case of a 55-year-old patient with lipemia retinalis, which deteriorated his visual acuity. The patient had an extremely hi...

متن کامل

Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence

INTRODUCTION In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector labor...

متن کامل

Quantification of serum free light chain kappa and lambda by the SPAPLUS analyser.

OBJECTIVE Clinical assessment of the SPAPLUS® system for the determination of the serum free light chains kappa (κ FLC) and lambda (λ FLC) compared to the BNII®. DESIGN AND METHODS 126 serum specimens from our routine activity were analysed on two different analysers: the BNII® (immunonephelometry, Siemens) and the SPAPLUS® (turbidimetry, Binding Site). We compared the absolute values of the ...

متن کامل

The Stabilization of Serum Lipid Emulsions by Serum Phospholipids

Clarity of high lipid sera is closely correlated with elevated proportions of serum phospholipids, and lipemia (milkiness) with low proportions of phospholipids. Clear high lipid sera occur uniquely in obstructive jaundice, both intra- and extrahepatic in origin. Destruction of the polar nature of serum "lecithin" by enzymatic hydrolysis, using Cl. welchii lecithinase, results in a degree of li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2012