Quantitative assessment of inter-observer variability in target volume delineation on stereotactic radiotherapy treatment for pituitary adenoma and meningioma near optic tract
نویسندگان
چکیده
BACKGROUND To assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise. METHODS We quantitatively analyzed 21 plans made by 11 clinicians in seven CyberKnife centers. The clinicians were provided with a raw data set (pituitary adenoma and meningioma) including clinical information, and were asked to delineate the lesions and create a treatment plan. Their contouring and plans (10 adenoma and 11 meningioma plans), were then compared. In addition, we estimated the influence of differences in contouring by superimposing the respective contours onto a default plan. RESULTS The median planning target volume (PTV) and the ratio of the largest to the smallest contoured volume were 9.22 cm3 (range, 7.17-14.3 cm3) and 1.99 for pituitary adenoma, and 6.86 cm3 (range 6.05-14.6 cm3) and 2.41 for meningioma. PTV volume was 10.1±1.74 cm3 for group 1 with a margin of 1-2 mm around the CTV (n=3) and 9.28±1.8 cm3 (p=0.51) for group 2 with no margin (n=7) in pituitary adenoma. In meningioma, group 1 showed larger PTV volume (10.1±3.26 cm3) than group 2 (6.91±0.7 cm3, p=0.03). All submitted plan keep the irradiated dose to optic tract within the range of 50 Gy (equivalent total doses in 2 Gy fractionation). However, contours superimposed onto the dose distribution of the default plan indicated that an excessive dose 23.64 Gy (up to 268% of the default plan) in pituitary adenoma and 24.84 Gy (131% of the default plan) in meningioma to the optic nerve in the contours from different contouring. CONCLUSION Quality assurance revealed inter-observer variability in contour delineation and their influences on planning for pituitary adenoma and meningioma near optic tract.
منابع مشابه
Challenges for Quality Assurance of Target Volume Delineation in Clinical Trials
In recent years, new radiotherapy techniques have emerged that aim to improve treatment outcome and reduce toxicity. The standard method of evaluating such techniques is to conduct large scale multicenter clinical trials, often across continents. A major challenge for such trials is quality assurance to ensure consistency of treatment across all participating centers. Analyses from previous stu...
متن کاملTarget delineation and optimal radiosurgical dose for pituitary tumors
Stereotactic radiosurgery (SRS) delivered as either single-fraction or multi-fraction SRS (2-5 fractions) is frequently employed in patients with residual or recurrent pituitary adenoma. The most common delivery systems used for SRS include the cobalt-60 system Gamma Knife, the CyberKnife (CK) robotic radiosurgery system, or a modified conventional radiotherapy machine (linear accelerator, LINA...
متن کاملA New Index to Measure Intra-observer Variation in Delineating GTV Primary in Head and Neck Cancer
A critical step in radiotherapy treatment planning process is to accurately locate the tumor and determine its extent. Variability in gross tumor volume (GTV) delineation is a major source of systematic error in conformal radiotherapy. CT scan is the principle source of imaging data used for defining GTV for planning conformal therapy. CT is widely available less costly and compatible with radi...
متن کاملFractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs.
BACKGROUND Benign tumors of the skull base are a challenge when delivering radiotherapy. An appropriate choice of radiation technique may significantly improve the patient's outcomes. Our study aimed to compare the dosimetric results of fractionated stereotactic radiotherapy between non-coplanar dynamic arcs and coplanar volumetric modulated arctherapy (Rapidarc®). METHODS Thirteen patients t...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2011