Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation.

نویسندگان

  • S Inoue
  • N Nishimine
  • K Kitaguchi
  • H Furuya
  • S Taniguchi
چکیده

BACKGROUND Poor positioning of an endobronchial double lumen tube (DLT) could affect oxygenation during one lung ventilation (OLV). We set out to relate DLT position to hypoxaemia and DLT misplacement during OLV. METHODS We recruited 152 ASA physical status I-II patients about to have elective thoracic surgery. The trachea was intubated with a left-sided DLT. Tube position was assessed by fibre-optic scope and correction was made after patient positioning and during OLV. If Pa(O(2)) was less than 10.7 kPa, the DLT position was checked and then PEEP, continuous positive airway pressure (CPAP), oxygen insufflation, or two lung ventilation (TLV) were tried. RESULTS The DLT was found to be misplaced in 49 patients (32%) after patient positioning, and in 38 patients (25%) during OLV. PEEP to the dependent lung, CPAP or apneic oxygen insufflation to the non-dependent lung, or brief periods of TLV, were applied in 46 patients (30%). Patients who had DLT malposition after placing the patient in the lateral position had a greater incidence of DLT malposition during OLV (59 vs 9%) and also required each intervention more frequently (57 vs 10%). Patients with DLT malposition during OLV also required interventions more often (84 vs 12%). CONCLUSIONS Patients who have DLT malposition after placing the patient in the lateral position had more DLT malposition during OLV and hypoxaemia during OLV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report.

For one-lung ventilation in many surgical cases, double-lumen endotracheal tubes are the first-line choice for airway management. For most cases, double-lumen endotracheal tubes are faster, easier to place, cheaper, and less prone to malposition than today's bronchial blocker devices. This report describes an elective tracheostomy and the use of a double-lumen endotracheal tube directly through...

متن کامل

Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker.

This study compared the modified BronchoCath double-lumen endotracheal tube with the Univent bronchial blocker to determine whether there were objective advantages of one over the other during anesthesia with one-lung ventilation (OLV). Forty patients having either thoracic or esophageal procedures were randomly assigned to one of two groups. Twenty patients received a left-side modified Bronch...

متن کامل

Hypoxaemia associated with one-lung anaesthesia: new discoveries in ventilation and perfusion.

One-lung ventilation is required when providing anaesthesia for operative procedures in the thoracic cavity. During this process, hypoxaemia is reported to occur with an incidence of approximately 5–10%. Unfortunately, hypoxaemia affects postoperative outcome as there is an increased risk of complications such as cognitive dysfunction, atrial fibrillation, renal failure, and pulmonary hypertens...

متن کامل

Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes.

T here are no objective criteria for selecting the size of a double-lumen endobronchial tube (DLT) (1). An inappropriately sized DLT can cause airway trauma and interfere with oxygenation and lung separation during one-lung ventilation. The goal of this study was to determine if measurement of tracheal diameter from the preoperative chest radiograph can be used to predict which size DLT to choo...

متن کامل

Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-

Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 92 2  شماره 

صفحات  -