Statistical comparison of blood glucose as determined by several test-strip procedures and by a hexokinase procedure.

نویسندگان

  • T C Stewart
  • R M Kleyle
چکیده

We report a new statistical tool for comparing several dry-reagent strip procedures for whole blood glucose, which produce data in both digital and ordinal form, with results by the well-studied hexokinase-glucose-6-phosphate dehydrogenase procedure coupled to NAD+-NADH. Our use of "ordinal comparison unit" allows for a more equitable comparison of such data. These strip procedures produce biases of -2.21 to 1.74 ordinal comparison units over the range of glucose values corresponding to hypoglycemia and hyperglycemia, as compared with results by the hexokinase procedure, but they are essentially equivalent when compared with each other.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد

Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...

متن کامل

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Abstract         Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...

متن کامل

Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197.

BACKGROUND Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. METHODS In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), G...

متن کامل

Qualitative and Semi-Quantitative Comparison of an Rk39 Strip Test and Direct Agglutination Test for Detection of Anti-Leishmania Donovani Antibodies in the Sudan

Background: Until now, the comparison of the rK39 strip test (RKT) and direct ag-glutination test (DAT) for detection of visceral leishmaniasis (VL) is exclusively based on either positive or negative qualification of the reaction outcome. Objective: In this study, we compared the diagnostic performance of RKT and DAT for VL both qualitatively and semi-quantitatively. Methods: For comparison ba...

متن کامل

Comparison of Diagnostic Procedures for Platelet Products Contaminated with Strains of Staphylococcus Epidermidis and Klebsiella

Abstract Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration. Material and Methods: This laboratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 1983