The influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats: an experimental and simulation study

نویسندگان

  • Aldo José Fontes-Pereira
  • Marcio Amorim
  • Fernanda Catelani
  • Daniel Patterson Matusin
  • Paulo Rosa
  • Douglas Magno Guimarães
  • Marco Antônio von Krüger
  • Wagner Coelho de Albuquerque Pereira
چکیده

BACKGROUND Low-intensity physiotherapeutic ultrasound has been used in physical therapy clinics; however, there remain some scientific issues regarding the bone-healing process. The objective of this study was to investigate the influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats. METHODS Twenty-two male adult rats were assessed quantitatively and qualitatively using radiographic, biochemical, and histological analyses. Numerical simulations were also performed. Fractures in animals in the ultrasound group (n = 11) were treated with low-intensity ultrasound (pulsed mode, duty cycle 20 %) for 10 min daily at an intensity of 40 mW/cm2 SATA (1.0 MHz) for 10 days. Fractures in animals in the control group (n = 11) were not treated. RESULTS Alkaline phosphatase levels were non-significantly higher in the ultrasound group than in the control group in the time intervals considered (t(13) = 0.440; 95 % confidence interval (CI) -13.79 to 20.82; p = 0.67). Between-group serum calcium levels were also not significantly different (t(13) = -0.842; 95 % CI -0.48 to 0.21; p = 0.42). Finally, there were no significant differences in radiological scores between the two groups (U = 118; 95 % CI -1.99 to 1.99; p = 0.72). However, the diameter of the newly formed bone tissue was greater and more evident in the ultrasound group. CONCLUSIONS Thirteen days after fracture, there was no significant between-group differences in bone-healing processes, although the increased alkaline phosphatase levels and diameter of new bone tissue need to be further investigated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR

We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...

متن کامل

اثر امواج فراصوتی کم توان بر رشد استخوان در داخل کانال ایمپلانت تیتانیومی

The effect of ultrasound waves with low intensity on reducing the time of repair and healing of bone fracture has been known. The present research was undertaken to investigate the effect of ultrasound waves on acceleration of bone growth and, finally, on repair and healing of surgical area using in-vivo animal experiment. In this study, 20 titanium implants with proper dimensions wer...

متن کامل

LOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING

In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...

متن کامل

Effects of Low-Intensity Continuous Ultrasound on Hematological Parameters of Rats

Background:Low intensity ultrasound (US) has some well-known bio-effects which are of great importance to be considered.Objectives: We conducted the present study to investigate the effects of low intensity continuous ultrasound on blood cells count in rat.Methods: Rats were anesthetized and blood samples were collected before US exposure. Then, they were exposed to US with nominal intensity of...

متن کامل

Effects of Low-Level Helium-Neon Laser Therapy on Healing of Partial Thickness Defect of Experimental Induced Diabetic Rats

Purpose: The aim of present study was to study the effects of low-level helium–neon laser irradiation on biomechanical properties of tibiae partial bone defect in streptozotocin–diabetic rat. Materials and Methods: Twenty male rats were used .Diabetes was induced in rats by one time intraperitoneal injection of 60 mg/kg streptozotocin .After one month ,under sterile conditions and general anes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016