High-resolution TOF with RPCs
نویسندگان
چکیده
In this work, we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically accurate, thin gas gaps and state-of-the-art electronics yielded an overall (detector plus electronics) timing accuracy better than 50 ps s with a detection efficiency up to 99% for MIPs. Single gap chambers were also tested in order to clarify experimentally several aspects of the mode of operation of these detectors. These results open perspectives of affordable and reliable high granularity large area TOF detectors, with an efficiency and time resolution comparable to the existing scintillator-based TOF technology but with a significantly, up to an order of magnitude, lower price per channel. r 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Performances of multi - gap timing RPCs for relativistic ions in the range Z = 1 - 6
We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (γβ =2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard 'off the shelf' 4-gap timing RPCs from the new HADES ToF wall. The resolution worsened to 100 ps for ∼ 1 kHz/cm 2 proton flux and for ∼ 100 Hz/cm 2 Carbon flux. The chambers were operate...
متن کاملOptimization of RFM's Structure Using a New Reformulation of PSO in Case of Limited GCPs
Metaheuristic algorithms have been widely used in determining the optimum rational polynomial coefficients (RPCs). By eliminating a number of unnecessary RPCs, these algorithms increase the accuracy of geometric correction of high-resolution satellite images. To this end, these algorithms use ordinary least squares and a number of ground control points (GCPs) to determine RPCs' values. Due to t...
متن کاملTiming RPCs in FOPI
The status of our development of strip anode MRPCs in the framework of the FOPI-ToF upgrade project is reviewed. For the counter readout we have developed a fast FEE (front-end-electronics) offering a high gain ða 200Þ at high bandwidth ðdf 1000MHzÞ and a new TAC-digitization system with an internal resolution of stp15 ps. In order to optimize the signal shape variations, strip/pitch configurat...
متن کاملSingle-gap timing RPCs with bidimensional position-sensitive readout for very accurate TOF systems
In this work, we report the development and performance of single-gap timing RPCs equipped with a 3mm FWHM resolution bidimensional position-sensitive readout and reaching a timing resolution of 55 ps s at an efficiency of 75% for MIPs. These chambers are aimed to be applied in a multilayer geometry, forming small and very accurate TOF systems. The avalanche localization capability would provid...
متن کاملHigh-resolution timing of MIPs with RPCs } a model
Resistive Plate Chambers made with glass and metal electrodes forming accurately spaced gas gaps of a few hundred micrometers have reached timing accuracies below 50ps p with e$ciencies above 95%. This type of detector, operating at atmospheric pressure with non-#ammable gases, seems well suited for large-area TOF systems, providing performances comparable to the existing scintillator-based TOF...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002