Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.

نویسندگان

  • Miguel Alcaraz-Baños
  • María del Carmen Parra-Pérez
  • David Armero-Barranco
  • Francisco Velasco-Hidalgo
  • Esteban Velasco-Hidalgo
چکیده

INTRODUCTION The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. OBJECTIVE To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. MATERIAL AND METHODS A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. RESULTS According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. CONCLUSION there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان رعایت اصول حفاظت در برابر اشعه در دانشکده‌های دندانپزشکی سراسر کشور

Background and Aim: In recent decades many guidelines has been conducted by radiation protection organizations about radiation protection in dentistry. This study was designed to evaluate the observance of these guidelines in educational clinics of all dental schools in Iran.Materials and Methods: In this cross-sectional study a questionnaire based on National Radiation Protection guidelines wa...

متن کامل

Radiation protection principles observance in Iranian dental schools

Background: In recent decades many guidelines has been conducted by radiation protection organizations about radiation protection in dentistry. This study aimed to evaluate the observance of these guidelines in educational clinics of all dental schools in Iran. Material and Methods: In this cross-sectional study a self-administered questionnaire, based on National Radiation Protection ...

متن کامل

Absorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models

Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

The Correlation Relationship between Concepts of Learning Organization and Safety Culture in Iran’s Nuclear and Radiological Industries

Introduction: The formation and evolution of culture in organizations are related to the learning experiences of their members over time. In this regard, the present study was conducted to empirically investigate the correlation relationship between the Learning Organization (LO) and safety culture concepts in Iran’s nuclear and radiological industries. Material and Methods: A theoretical mode...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medicina oral, patologia oral y cirugia bucal

دوره 14 10  شماره 

صفحات  -

تاریخ انتشار 2009