X-ray micro-CT with a displaced detector array.

نویسنده

  • Ge Wang
چکیده

Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field of view, and formulate a weighting scheme for artifact-free reconstruction. Then, we perform numerical simulation with the Shepp-Logan phantom to demonstrate the feasibility in fan-beam and cone-beam geometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray micro-CT with a displaced detector array: application to helical cone-beam reconstruction.

In x-ray micro-CT applications, it is useful to increase the field of view by offsetting a two-dimensional (2D) detector array. In this technical note, we briefly review the methods for image reconstruction with an asymmetric 2D detector array, elaborate on the use of an associated weighting scheme in the case of helical/spiral cone-beam scanning, and perform a series of numerical tests to demo...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Comparison of X-ray Inspection Systems for BGNCCGA Quality Assurance and Crack Detection

The use of x-ray technique now become an additional inspection tool requirement for quality control and unique defect due to manufacturing for implementation of advanced electronic packages such as ball grid array (BGAs) and chip scale packages (CSPs). Recently, four x-ray systems were evaluated for their defect detection capability especially for damagekracks induced during thermal cycling of ...

متن کامل

An Efficient Ring Artifact Reduction Method Based on Projection Data for Micro-CT Images

Ring artifacts are very troublesome in a flat-panel based micro computed tomography (micro-CT) since they might severely degrade visibility of the micro-CT images. Unlike ring artifacts in other types of micro-CTs such as image-intensifier based micro-CT, ring artifacts in a flat-panel detector based micro-CT are hardly removable since the sensitivity of the pixel elements in a flat-panel detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 2002