Evaluation of differential magnification during brain SPECT acquisition.

نویسندگان

  • D C Vines
  • M Ichise
چکیده

OBJECTIVE We developed a modification of the acquisition zoom technique, referred to as differential magnification (DM), to improve the pixel resolution with fanbeam collimators. This study evaluated the effects of DM on brain SPECT image quality. METHODS SPECT imaging was performed using a triple-head camera with and without DM for a line source in air, Jaszczak and Hoffman phantoms, and 15 clinical patients having regional cerebral blood-flow scans with 99mTc ECD. Full width at half maximum (FWHM) and contrast ratios were measured on the line source and Jaszczak phantom data, respectively. Visual image evaluation was performed by 2 independent, blinded observers for the Hoffman brain phantom images and clinical patient studies. RESULTS FWHM improved on the fanned axis (transverse plane) by 0.05 mm (P < 0.001), and the unfanned axis (longitudinal plane) by 0.66 mm (P < 10(-6)), when DM was used. The mean improvement of contrast ratios for the spheres on the Jaszczak phantom with DM was 11.4% (P < 0.004). The images with DM were rated superior to those without, for the Hoffman brain phantom and the clinical patients. CONCLUSION This study has demonstrated that SPECT acquisition with fanbeam collimators and DM significantly improves both FWHM and image contrast, resulting in superior image quality. DM techniques may be useful in improving clinical brain SPECT images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of role of brain SPECT in diagnosis of post stroke dementia [Persian]

Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and ...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

Qualitative evaluation of filter function in brain SPECT [Persian]

Introduction: Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Methods: Forty five patient’s data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1999