Usefulness of hook wire localization biopsy under imaging guidance for nonpalpable breast lesions detected radiologically
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate the usefulness of hook wire localization biopsy under imaging guidance for nonpalpable breast lesions detected radiologically. METHODS This was a descriptive study conducted at the Department of Radiology, Aga Khan University Hospital, Karachi. All patients undergoing needle localization biopsy of a nonpalpable breast lesion under mammographic or ultrasound guidance between January 2009 to December 2010 were included in the study. Patients with incomplete medical records were excluded. All patients' mammograms or ultrasound were categorized using BI-RADS(®) assessment categories. The percentages of benign and malignant lesions were determined by pathological examination of surgically removed specimens. A correlation was sought between preoperative imaging assessment and the final diagnosis. The complications associated with the procedure were also recorded. RESULTS A total of 151 biopsies were carried out, of which 80 were performed under mammographic guidance and 71 were performed under ultrasound guidance. The mean age of the patients was 51.89 years. The overall malignancy rate was 25.16%. Of 93 cases reported radiologically as malignant, 60 turned out to be malignant, and of the 58 cases reported as benign on imaging, three proved to be malignant on histopathology. The sensitivity of imaging findings was 95% and the specificity was 62%. The malignancy rate was 5% for benign lesions and 64% for malignant lesions, respectively. There were no complications related to wire localization, and only two patients had minor complications following surgical excision, giving a complication rate of 1.32%. CONCLUSION Hook wire localization biopsy is a safe and effective procedure for definitive diagnosis of suspicious lesions on imaging, and is more helpful if the imaging findings are suspicious.
منابع مشابه
Diagnostic Value of Hook Wire Localization Technique for Non-Palpable Breast Lesions
BACKGROUND The aim of this study was to investigate the validity of hook wire localization biopsy for non-palpable breast lesions which were detected by ultrasonography (USG) or mammography (MMG). METHODS In this retrospective study, USG or MMG-guided hook wire localization technique was performed on 83 patients who had non-palpable breast lesions. Then histopathological examination was perfo...
متن کاملSignificance of methylene blue dye for localization biopsy of nonpalpable breast lesions.
BACKGROUND AND OBJECTIVE With advances in mammographic equipment and techniques, more and more nonpalpable breast lesions have been detected. This study was to investigate the application of methylene blue dye for localized biopsy to diagnose nonpalpable breast lesions. METHODS In total 138 patients with suspicious malignant, nonpalpable breast lesions between August 2002 and October 2006 wer...
متن کاملPrebiopsy localization of nonpalpable breast lesions.
Radiologically guided localization procedures are indicated pre-operatively when breast lesions are nonpalpable. The results of 42 percutaneous hookwire localizations over a period of 3 years are described. Of the total, 7 (17%) were found to be malignant. Biopsy was indicated by mammographically detected mass in 48%, by microcalcifications in 40% and by microcalcifications with an associated m...
متن کاملReducing the cost of diagnosis of breast carcinoma: impact of ultrasound and imaging-guided biopsies on a clinical breast practice.
BACKGROUND The objective of this study was to determine whether the use of ultrasound and percutaneous breast biopsies in patients with screen-detected nonpalpable abnormalities can reduce benign open surgical biopsies of the breast without increasing cost or sacrificing detection of potentially curable breast carcinomas. METHOD Using a computerized mammography database and consecutive logs o...
متن کاملDislocability of Localization Devices for Nonpalpable Breast Lesions: Experimental Results
Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2012