The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses.
نویسنده
چکیده
This review considers the causes of loosening of prosthetic joint replacement paying attention to the biological mechanisms rather than other effects that are physical, such as component fracture and other failure related to mechanical problems. Infection accounts for approximately 1.5 per cent of joint loosening and when it occurs it is a cause of serious concern to the surgeon. The loosening of prosthetic joints in the absence of infection is by far the most common reason for revision surgery and is known as aseptic loosening. While this may be multifactorial in terms of causation, and non-biological factors may contribute significantly in a particular individual, a significant part is undoubtedly played by the generation of wear debris, mainly from the bearing surfaces of the joint, and the cellular reaction to this in the implant bed. Phagocytic cells (macrophages and multinucleated giant cells) are the ones that remove foreign material from the tissues, and the ways in which these cells function in the interface between implant and bone are described. Mediators produced locally include numerous cytokines, enzymes and integrins. There is evidence for interactions between macrophages and locally recruited lymphocytes, which may or may not give rise to an immunologically mediated process.Sensitization of individuals having metal implants in place has been shown by positive skin tests or blood lymphocyte transformation tests and in these cases has been accompanied by loosening and failure of the replacement joint. The question remains as to whether this process is also present in a proportion of individuals with aseptic loosening in the absence of clearly defined clinical evidence of sensitization.Numerous studies performed by the author's group and, latterly, by others suggest that the cellular reactions detected in the tissues in cases of aseptic loosening are indeed those of contact sensitization. There is good evidence to show that a type IV cell-mediated immune reaction is taking place, with TH1 cell involvement and active antigen presentation. The extent to which sensitization is present in individual cases of aseptic loosening remains a subject for further work and this needs all the sophisticated molecular methods now available to modern biology to be applied in appropriate prospective clinical studies coupled with experimental models in vitro and in vivo. Immunological processes may play a more important part in joint loosening than previously considered.
منابع مشابه
Wear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material
Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/o...
متن کاملMetal sensitivities and orthopaedic implants revisited: the potential for metal allergy with the new metal-on-metal joint prostheses.
The potential of metal-containing orthopaedic prostheses to induce problems through metal allergy taxes dermatologists and orthopaedic surgeons alike. Metal-on-plastic joint replacements are not thought to induce metal allergy but wear products, principally polypropylene particles, produce a foreign body reaction in bone and may lead to aseptic loosening of the joint. Orthopaedic surgeons are i...
متن کاملPolyethylene Wear in Anatomic and Reversed Shoulder Prostheses
INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...
متن کاملSequentially Annealed Highly Cross-linked Polyethylene Reduced In Vivo Wear Particle Generation In TKA
Introduction: Polyethylene wear particles induce macrophages to release cytokines, which can lead to osteolysis and aseptic loosening of total joint prostheses. The generation of polyethylene wear particles is one of the most important factors that affect the midterm and long-term clinical results associated with total knee arthroplasty (TKA). Therefore, to achieve better long-term results for ...
متن کاملWear particles enhance autophagy through up-regulation of CD147 to promote osteoclastogenesis
Objective(s): The study aimed to uncover the underlying mechanism linking wear particles to osteoclast differentiation, and we explored the effect of titanium particles of different sizes on CD147 expression and autophagy in macrophages. Materials and Methods: Effects of titanium particles on CD147 and RANKL mRNA were detected by QPCR; protein level of CD147 and Beclin-1 were detected by Wester...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Royal Society, Interface
دوره 5 28 شماره
صفحات -
تاریخ انتشار 2008