Transcatheter Atrial Septal Defect Closure Using Occlutech Figulla Device: A Two-Center Experience
نویسندگان
چکیده
BACKGROUND Despite several reports regarding the use of the Occlutech Figulla® Flex septal occluder (OFFSO) in adults, there are few reports on its use in children. We sought to study the result of the transcatheter closure of atrial septal defect (ASD) using the OFFSO in children ≤12 years. METHODS We enrolled 45 consecutive patients, ranging from 2.5 to 12 years of age, in two large pediatric cardiovascular centers. All the children underwent complete echocardiographic examination before the procedure. Defect/device ratio and device/weight ratio were measured. The device diameter to the cardiac diameter ratio (DD/CD ratio) in anteroposterior projection after device release and the DD/CD index were calculated by dividing the DD/CD ratio by the body surface area. RESULTS Of the 45 enrolled patients, 25 (55%) were female. The range and mean ± standard deviation (SD) of age were 2.5 to 12 years and 6.8 ± 2.5 years, respectively. The range and mean ± SD weight were 8.5 to 37.0 kg and 19.7 ± 7.2 kg, respectively. Successful implantation was performed in all the patients. No major complications occurred in any of the subjects. We encountered one cobra head deformity in one patient. Neither residual shunt nor conduction abnormality was observed in any of the cases. CONCLUSION Transcatheter ASD closure using the OFFSO was effective in our pediatric patients. Although this device needs relatively larger delivery sheaths, its use is safe while closing even large defects in children.
منابع مشابه
The efficiency and safety of percutaneous closure of secundum atrial septal defects with the Occlutech Figulla device: initial clinical experience.
OBJECTIVES We evaluated the efficiency and safety of the Occlutech Figulla device in percutaneous closure of secundum atrial septal defects (ASD). STUDY DESIGN The study included 28 patients (17 women, 11 men; mean age 43 years) who underwent percutaneous transcatheter closure using the Occlutech Figulla device for secundum ASDs causing a hemodynamically significant shunt. Defect size was est...
متن کاملTranscatheter Closure of Atrial Septal Defect in a Patient with Cor Triatriatum Sinister and Atrial Septal Defect
Cor triatriatum sinister is a rare congenital heart disease and rarely found in adults. The authors describe an asymptomatic 20-year old man presenting with heart murmur by check up. Transthoracic and transesophageal echocardiogram demonstrate atrial septal defect (ASD) secundum 26 mm and cor triatriatum sinister with 20 mm of fenestration. Transcatheter closure of ASD using Occlutech Figulla(R...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملTranscatheter closure of secundum ASD using Occlutech Figulla-N device in symptomatic children younger than 2 years of age.
INTRODUCTION Atrial septal defect (ASD) transcatheter occlusion techniques have become alternatives to surgical procedures. We evaluated the efficiency and safety of the Occlutech Figulla-N device in percutaneous closure of secundum ASDs in symptomatic children younger than 2 years of age. METHODS The study included 17 patients (9 girls, 8 boys; mean age, 10.3 ± 2.1 months). Mean weight was 7...
متن کاملPercutaneous closure of a postoperative residual atrial septal defect with the Occlutech Figulla Occluder device.
A 67-year-old male patient with an eight-month history of operation for mitral valve repair and secundum atrial septal defect (ASD) presented with complaints of fatigue and shortness of breath. Transthoracic echocardiography showed a residual ASD resulting from separation of a pericardial patch. Qp/Qs rate was 3.2. The diameter of the residual defect measured by transesophageal echocardiography...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013