Objective and Subjective Assessment of Digital Pathology Image Quality
نویسندگان
چکیده
The quality of an image produced by the Whole Slide Imaging (WSI) scanners is of critical importance for using the image in clinical diagnosis. Therefore, it is very important to monitor and ensure the quality of images. Since subjective image quality assessments by pathologists are very time-consuming, expensive and difficult to reproduce, we propose a method for objective assessment based on clinically relevant and perceptual image parameters: sharpness, contrast, brightness, uniform illumination and color separation; derived from a survey of pathologists. We developed techniques to quantify the parameters based on content-dependent absolute pixel performance and to manipulate the parameters in a predefined range resulting in images with content-independent relative quality measures. The method does not require a prior reference model. A subjective assessment of the image quality is performed involving 69 pathologists and 372 images (including 12 optimal quality images and their distorted versions per parameter at 6 different levels). To address the inter-reader variability, a representative rating is determined as a one-tailed 95% confidence interval of the mean rating. The results of the subjective assessment support the validity of the proposed objective image quality assessment method to model the readers’ perception of image quality. The subjective assessment also provides thresholds for determining the acceptable level of objective quality per parameter. The images for both the subjective and objective quality assessment are based on the HercepTest slides scanned by the Philips Ultra Fast Scanners, developed at Philips Digital Pathology Solutions. However, the method is applicable also to other types of slides and scanners.
منابع مشابه
Quality Assessment of Turfgrasses Using NTEP Method Compared to an Image-Based Scoring System
The current methods of turfgrass evaluations are often based on human-based assessment methods. However, eliminating subjective errors from such evaluations is often impossible. This research compared the accuracy of human-based and digital image processing-based methods for quality assessment of turfgrasses. Four turfgrass plots were evaluated using the two mentioned methods. In the human-base...
متن کاملQuality Assessment of Turfgrasses Using NTEP Method Compared to an Image-Based Scoring System
The current methods of turfgrass evaluations are often based on human-based assessment methods. However, eliminating subjective errors from such evaluations is often impossible. This research compared the accuracy of human-based and digital image processing-based methods for quality assessment of turfgrasses. Four turfgrass plots were evaluated using the two mentioned methods. In the human-base...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملA Study of Quality Assessment Techniques For Fused Images
290 Abstract: Critical image processing tasks can be efficiently executed by fusion of images taken from range of distributed sensors. Advancements in digital image processing and communication technology with invent of new sensors experiencing the excessive need of effective image quality assessment of image fusion techniques. Various metrics have been discussed for quality measurement of fuse...
متن کاملImage quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015