Complications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.

نویسندگان

  • Sang Yeul Lee
  • Jae Woo Jang
  • Helen Lew
  • Sung Joo Kim
  • Hye Young Kim
چکیده

PURPOSE In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket. METHODS Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed using the chi-square test. RESULTS Extrusion rates were significantly lower in the sleeved peg system (10.8%) compared to the nonsleeved peg system (27.2%) (P =.005). The other complications related to motility peg placement were granulation tissue overgrowth (4.2%), hydroxyapatite exposure around peg head (3.0%), and decentered peg (1.9%). CONCLUSIONS To minimize peg extrusion, the sleeved peg was better than the nonsleeved peg for use in primary motility peg placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chronic Orbital Inflammation Associated to Hydroxyapatite Implants in Anophthalmic Sockets

Purpose We report 6 patients who received a hydroxyapatite (HA) orbital implant in the socket and developed chronic orbital inflammation unresponsive to conventional medical therapy. Case Reports We assisted 6 cases (4 males, 2 females) who received an HA orbital implant in the socket between 2015 and 2016 at King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia, and developed chronic orb...

متن کامل

Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant expos...

متن کامل

Complications of motility peg placement for porous hydroxyapatite orbital implants.

AIM To evaluate the complications associated with pegging of porous hydroxyapatite orbital implants. METHODS Complications associated with pegging were retrospectively reviewed from the charts of 100 of 133 patients with hydroxyapatite implantation from 1993 to 2000. RESULTS 48 (48%) of the 100 hydroxyapatite implanted patients who had undergone pegging were found to have problems with thei...

متن کامل

CLINICAL SCIENCE Long term follow up of bone derived hydroxyapatite orbital implants

Aims: To document the long term experience of bone derived hydroxyapatite orbital implants and compare results using scleral wrapped implants with those not using sclera. Methods: This retrospective case series reviewed the long term follow up of 118 patients with 120 eyes which had undergone enucleation and bone derived hydroxyapatite orbital implant insertion at Dunedin Hospital from 1977 unt...

متن کامل

Long term follow up of bone derived hydroxyapatite orbital implants.

AIMS To document the long term experience of bone derived hydroxyapatite orbital implants and compare results using scleral wrapped implants with those not using sclera. METHODS This retrospective case series reviewed the long term follow up of 118 patients with 120 eyes which had undergone enucleation and bone derived hydroxyapatite orbital implant insertion at Dunedin Hospital from 1977 unt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of ophthalmology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2002