Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
نویسندگان
چکیده
Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU.
منابع مشابه
Central Venous Catheter-Related Tachycardia in the Newborn: Case Report and Literature Review
Central venous access is an important aspect of neonatal intensive care management. Malpositioned central catheters have been reported to induce cardiac tachyarrhythmia in adult populations and there are case reports within the neonatal population. We present a case of a preterm neonate with a preexisting umbilical venous catheter (UVC), who then developed a supraventricular tachycardia (SVT). ...
متن کاملTerm Neonate With Liver Laceration, Obstructive Uropathy, and Ascites—Secondary to Extravasation of Total Parenteral Nutrition
We report a rare, but serious, complication of a malpositioned umbilical venous catheter in a term male infant who developed laceration, hematoma, and necrosis of liver, ascites, and left-sided obstructive uropathy secondary to extravasation of total parenteral nutrition. Abdominal paracentesis confirmed the presence of parenteral nutrition in the peritoneal cavity. Although, the umbilical veno...
متن کاملPericardial effusion with cardiac tamponade caused by a central venous catheter in a very low birth weight infant
With more and more extreme premature and very low-birth weight babies being resuscitated, umbilical central venous catheterisation is now being used more frequently in neonatal intensive care. One of the life-threatening complications is pericardial effusion and cardiac tamponade; however, it is potentially reversible when it is caught in time. The authors present a case of cardiac tamponade fo...
متن کامل[Cardiac tamponade associated with umbilical venous catheter (UVC) placed in inappropriate position].
Umbilical venous catheter (UVC) is widely used in neonatal intensive care units. Pericardial effusion is an uncommon but life-threatening complication; and tamponade have been reported in 3% of neonates having such catheters. We present a case of cardiac tamponade as a complication of venous catheter in a neonate. The patient was diagnosed at the appropriate time by echocardiography and the per...
متن کاملSterile hepatic abscess due to umbilical venous catheterization.
A preterm infant with isolated fetal ascites was admitted to the neonatal intensive care unit due to the appearance of respiratory distress at birth. An umbilical venous catheter (UVC) was inserted. Abdominal ultrasonography (US) showed localization of the catheter tip in the portal vein. It was removed and replaced with a newer one. UVC tip location was confirmed with X-ray. His condition had ...