Retardance and flicker modeling and characterization of electro-optic linear retarders by averaged Stokes polarimetry.
نویسندگان
چکیده
A polarimetric method for the measurement of linear retardance in the presence of phase fluctuations is presented. This can be applied to electro-optic devices behaving as variable linear retarders. The method is based on an extended Mueller matrix model for the linear retarder containing the time-averaged effects of the instabilities. As a result, an averaged Stokes polarimetry technique is proposed to characterize both the retardance and its flicker magnitude. Predictive capability of the approach is experimentally demonstrated, validating the model and the calibration technique. The approach is applied to liquid crystal on silicon displays (LCoS) using a commercial Stokes polarimeter. Both the magnitude of the average retardance and the amplitude of its fluctuation are obtained for each gray level value addressed, thus enabling a complete phase characterization of the LCoS.
منابع مشابه
Averaged Stokes polarimetry applied to evaluate retardance and flicker in PA-LCoS devices.
Recently we proposed a novel polarimetric method, based on Stokes polarimetry, enabling the characterization of the linear retardance and its flicker amplitude in electro-optic devices behaving as variable linear retarders. In this work we apply extensively the technique to parallel-aligned liquid crystal on silicon devices (PA-LCoS) under the most typical working conditions. As a previous step...
متن کاملPredictive capability of average Stokes polarimetry for simulation of phase multilevel elements onto LCoS devices.
Parallel-aligned (PA) liquid-crystal on silicon (LCoS) microdisplays are especially appealing in a wide range of spatial light modulation applications since they enable phase-only operation. Recently we proposed a novel polarimetric method, based on Stokes polarimetry, enabling the characterization of their linear retardance and the magnitude of their associated phase fluctuations or flicker, e...
متن کاملPrecision Measurements Using Semiconductor Light Sources: Applications in Polarimetry and Spectroscopy
Precision Measurements Using Semiconductor Light Sources: Applications in Polarimetry and Spectroscopy Matthew J. Romerein This thesis comprises two parts: Part I describes a method to improve the accuracy with which the polarization state of light can be characterized by the rotating quarter-wave plate technique. Through detailed analysis, verified by experiment, we determine the positions of ...
متن کاملAnalytical model of scanning laser polarimetry for retinal nerve fiber layer assessment.
PURPOSE To develop a quantitative understanding of scanning laser polarimetry (SLP) for retinal nerve fiber layer (RNFL) assessment in glaucoma diagnosis and management. METHODS The Mueller calculus was used to model the polarization optics of SLP. A birefringent retinal structure (RNFL or macula) was represented as a circularly symmetric linear retarder with a radial slow axis. The birefring...
متن کاملOptical system for measuring the spectral retardance function in an extended range
Background: Optical retarders are key elements for the control of the state of polarization of light, and their wavelength dependance is of great importance in a number of applications. Methods: We apply a well-known technique for determinig the spectral retardance by measuring the transmission spectra between crossed or parallel polarizers. But we we develop an optical system to perform this m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 39 4 شماره
صفحات -