Hygroscopic growth and activation of HULIS particles: experimental data and a new iterative parameterization scheme for complex aerosol particles

نویسندگان

  • M. Ziese
  • H. Wex
  • E. Nilsson
  • I. Salma
  • R. Ocskay
  • T. Hennig
  • A. Massling
  • F. Stratmann
چکیده

The hygroscopic growth and activation of two HULIS (HUmic LIke Substance) and one Aerosol-WaterExtract sample, prepared from urban-type aerosol, were investigated. All samples were extracted from filters, redissolved in water and atomized for the investigations presented here. The hygroscopic growth measurements were done using LACIS (Leipzig Aerosol Cloud Interaction Simulator) together with a HH-TDMA (High Humidity Tandem Differential Mobility Analyzer). Hygroscopic growth was determined for relative humidities (RHs) up to 99.75%. The critical diameters for activation were measured for supersaturations between 0.2 and 1%. All three samples showed a similar hygroscopic growth behavior, and the two HULIS samples also were similar in their activation behavior, while the Aerosol-Water-Extract turned out to be more CCN active than the HULIS samples. The experimental data was used to derive parameterizations for the hygroscopic growth and activation of HULIS particles. The concept of ρion (Wex et al., 2007a) and the Szyszkowski-equation (Szyszkowski, 1908; Facchini et al., 1999) were used for parameterizing the Raoult and the Kelvin (surface tension) terms of the Köhler equation, respectively. This concept proved to be very successful for the HULIS samples in the saturation range from RHs larger than 98% up to activation. It was also shown to work well with data on HULIS taken from literature. Here, different atmospheric life-times and/or different sources for the different samples showed up in different coefficients for the parameterization. However, the parameterization did not work out well for the Aerosol-Water-Extract. Correspondence to: H. Wex ([email protected])

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interactive comment on “Hygroscopic growth and activation of HULIS particles: experimental data and a new iterative parameterization scheme for complex aerosol particles” by M. Ziese et al

Review: The manuscript shows laboratory results on activation and hygroscopic growth (up to 99.75% relative humidity) of aerosol particles made by HULIS and HULIS plus other species. These experimental data are further used to derive parameterizations for HULIS hygroscopicity and activation. The work is interesting and worth publication with some modifications. 1) I suggest to the authors to di...

متن کامل

Hygroscopic growth and activation of HULIS particles

Hygroscopic growth and activation of HULIS particles: experimental data and a new iterative parameterization scheme for complex aerosol particles M. Ziese, H. Wex, E. Nilsson, I. Salma, R. Ocskay, T. Hennig, A. Massling, and F. Stratmann Leibniz-Intitute for Tropospheric Research, Permoser Strasse 15, 04318 Leipzig, Germany Lund University, Department of Nuclear Physic, P.O. Box 118, 221 00 Lun...

متن کامل

Calibration of LACIS as a CCN detector and its use in measuring activation and hygroscopic growth of atmospheric aerosol particles

A calibration for LACIS (Leipzig Aerosol Cloud Interaction Simulator) for its use as a CCN (cloud condensation nuclei) detector has been developed. For this purpose, sodium chloride and ammonium sulfate particles of known sizes were generated and their grown sizes were detected at the LACIS outlet. From these signals, the effective critical super-saturation was derived as a function of the LACI...

متن کامل

Hygroscopic growth and droplet activation of soot particles: uncoated, succinic or sulfuric acid coated

The hygroscopic growth and droplet activation of uncoated soot particles and such coated with succinic acid and sulfuric acid were investigated during the IN-11 campaign at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) facility. A GFG-1000 soot generator applying either nitrogen or argon as carrier gas and a miniCAST soot generator were utilized to generate soot particles. Diffe...

متن کامل

Hygroscopic properties of aerosol particles at high relative humidity and their diurnal variations in the North China Plain

The hygroscopic properties of submicron aerosol particles were determined at a suburban site (Wuqing) in the North China Plain among a cluster of cities during the period 17 July to 12 August, 2009. A High Humidity Tandem Differential Mobility Analyser (HH-TDMA) instrument was applied to measure the hygroscopic growth factor (GF) at 90%, 95% and 98.5% relative humidity (RH) for particles with d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008