An evaluation of the Celloscope 401 electronic blood cell counter.

نویسندگان

  • T R Lappin
  • A Lamont
  • M G Nelson
چکیده

For counting erythrocytes the instrument was precise, with a mean coefficient of variation of 1.21%. Erythrocyte counts showed close agreement with results obtained on a Coulter A electronic counter of proven accuracy. When the Celloscope 401 was modified by the manufacturers to eliminate electrical interference from other laboratory equipment, satisfactory precision and accuracy for white cell counting was obtained. Using cetrimide diluent the coefficient of variation was 1.6% but when using saponin/saline diluent the coefficient of variation was 3.5%. For leucocyte counting there was close agreement between duplicate tests performed on the Celloscope 401 and the Coulter S. The instrument was capable of satisfactory precision and accuracy in platelet counting, provided that the sedimentation method was used to obtain a platelet-rich plasma. The best results were obtained if a two-step dilution was carried out with a first dilution in 10% EDTA and a second in 2.5 mM cocaine in water. Using this method the precision study indicated a coefficient of variation of 3.11%. Close agreement was obtained between platelet counts on the Celloscope 401 when compared with the results obtained either by phase-contrast microscopy or using another electronic counter. Allowing for predilution and duplicate counts on each sample, the rate of throughput was approximately 32 samples per hour. Throughout the test period, the instrument remained electronically and mechanically stable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters

Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...

متن کامل

Evaluation of total and differential white blood cell counts in workers exposed to lead

Introduction: Lead is a toxic heavy metal that has adverse health effects on blood parameters. About 80% of lead produced is used in batteries, especially vehicle batteries. Therefore, the present study aimed to assess the hematological changes, including total and differential white blood cell (WBC) counts in battery workers exposed to lead, and compare with the non-exposed group. Materials a...

متن کامل

Infrared Counter-Countermeasure Efficient Techniques using Neural Network, Fuzzy System and Kalman Filter

This paper presents design and implementation of three new Infrared Counter-Countermeasure (IRCCM) efficient methods using Neural Network (NN), Fuzzy System (FS), and Kalman Filter (KF). The proposed algorithms estimate tracking error or correction signal when jamming occurs. An experimental test setup is designed and implemented for performance evaluation of the proposed methods. The methods v...

متن کامل

بررسی ضرورت کنترل کیفی دستگاههای شمارنده سلول های خونی در آزمایشگاههای تشخیص طبی

Background and aim:Blood cells have an important role in human healthy, so their shapes and numbers are defined as human healthy indexes. These factors are measured by cell counter machines. Presenting a high quality report according to cell counters output is dependant on their operational accuracy. Therefore it was necessary to do a study on quality control of blood cell counter machines in s...

متن کامل

Pre-marriage Sickle Cell Screening Program in South Region of Iran, A Pilot Study on 50 Cases of Sickle Trait

Background: Studies have demonstrated that sickle cell trait can be found in an asymptomatic healthy carrier with normal complete blood count (CBC) and red blood cell (RBC) indices. According to Iranian Ministry of Health bulletin instructions, prenuptial Thalassemia Screening Program (TSP) primarily depends on RBC indices which are measured through a routine CBC. Only when these levels are bel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 1972