A microprocessor-controlled anaesthetic vaporizer.

نویسندگان

  • C E Hahn
  • E Palayiwa
  • B R Sugg
  • D Lindsay-Scott
چکیده

A microprocessor-controlled anaesthetic vaporizer is described. Fresh gas is mixed in the correct proportions using two pulsed solenoid valves and a proportion of this passes through a third pulsed solenoid valve and is bubbled through liquid halothane. The temperature of the liquid agent is measured and the pulse frequency is modified to give the correct vapour concentration for the set flow rate and measured temperature. Initially, the vapour was produced by bubbling fresh gas through the agent in a conventional halothane bottle. However, because of the large liquid volume available, nitrous oxide was found to dissolve in large quantities in the halothane. A small volume vaporizer which was continually replenished from a reservoir was designed. Measurements of the vapour concentrations emerging from such a vaporizer were made and were found to agree with the set values +/- 0.1% v/v.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of ultrasonic energy to vaporize anaesthetic liquids.

Ultrasonic energy, provided by a commercially available water vaporizer, was used to vaporize methoxyflurane, halothane, and chloroform. The vaporizer was placed directly in the respiratory line, and the anaesthetic liquid was vaporized one drop at a time. Anaesthesia was maintained for periods up to 6 hr in horses, ponies, calves, sheep, dogs, and one pig. This method of vaporizing liquids is ...

متن کامل

Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery

Purpose. Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associated with the use of this system and to compare it with use of a conventional syringe. Methods. A pr...

متن کامل

Potentially fatal vaporizer incident.

EDITOR: We wish to report a potentially fatal critical incident that occurred during an elective operating theatre list. A similar problem [1] has been recently highlighted by the MHRA but without the emphasis of its potentially fatal nature (Fault in Draeger Vapor 2000/D-Vapor Vaporizer series with the interlocking device, MDA/2006/030) [2]. This series of vaporizers for isoflurane and sevo-fl...

متن کامل

Flow reversal through a Mark III halothane vaporizer.

A fault in the assembly of a Matrix Large Animal Circle anaesthetic machine resulted in reversal of fresh gas flow through the vaporizer. The fault was discovered only after the sudden development of excessive depth of anaesthesia in two equine patients. Laboratory investigations were conducted to determine the effect of flow reversal on vaporizer output. Results indicated that output concentra...

متن کامل

Overfill testing of anaesthetic vaporizers.

We tested six anaesthetic vaporizers with keyed filler adaptors to see if it was possible to overfill them. For those vaporizers which could be overfilled, the maximum level of overfill was determined and the effect of overfilling on the vaporizer output concentration was measured. Three of the vaporizers, the TEC 4, PPV Mk 1 and MIE Vapamasta 5, could be overfilled. In the case of the TEC 4 an...

متن کامل